Per-Class Conformal Risk Control for Multi-Label ECG Classification: Achieving Clinically-Justified False Negative Rate Guarantees.
Oussama El Allam, Mohamed Hamlich
Université Hassan II Casablanca ENSAM, 150 Bd du Nil, Casablanca, Grand Casablanca, 20670, Morocco.
Key points
From the paper's conclusion- Under PTB-XL-to-Chapman shift, macro class coverage fell from 94.3% to 45.5%, demonstrating that the guarantees do not transport without local recalibration.
Significance: Exact-binomial per-class risk control provides a transparent high-sensitivity operating point for ECG triage while making its specificity, prediction-set-size, calibration-support, and exchangeability limitations explicit.&#
Abstract
Automated electrocardiogram (ECG) classifiers require uncertainty procedures that address class-specific clinical risk in intrinsically multi-label data. Approach: We propose per-class risk-controlling prediction sets for multi-label ECG classification. For each diagnostic class, binary false-negative-rate (FNR) loss is calibrated with a one-sided exact-binomial upper confidence bound. The nine disease-specific targets are controlled simultaneously at 95% family-wise confidence using Bonferroni allocation. The final operating threshold is the more inclusive of the exact-binomial threshold and a conservative reference threshold derived from a concentration bound; this safeguard uses calibration data only and cannot weaken the exact guarantee. Main results: We evaluated the method on PTB-XL (21,388 retained recordings) and Chapman-Shaoxing (10,199 retained recordings), using a patient-disjoint PTB-XL split and fitting-partition-only normalisation. The proposed method met all 9/9 prespecified disease-specific FNR targets on held-out test sets and produced non-vacuous simultaneous exact-binomial guarantees for all nine targets; uniform standard conformal prediction met 5/9. Test FNR was 0.0% for myocardial infarction (exact 95% upper bound 0.35%, at 80.3% FPR), 1.0% for ST/T changes, and 0.3% for atrial fibrillation; the high-sensitivity operating point is purchased with substantially reduced specificity. Under PTB-XL-to-Chapman shift, macro class coverage fell from 94.3% to 45.5%, demonstrating that the guarantees do not transport without local recalibration. Significance: Exact-binomial per-class risk control provides a transparent high-sensitivity operating point for ECG triage while making its specificity, prediction-set-size, calibration-support, and exchangeability limitations explicit.
.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Explainable and High-Performance ECG-Informed Machine Learning and Deep Learning Framework for Cardiovascular Risk Prediction.Life (Basel, Switzerland) · 2026
- Target Recoverability under Selective Labels: A Failure Mode in ECG-Based Acute Coronary Syndrome PredictionarXiv · 2026
- AI-Assisted Multilabel Diagnosis of 12-Lead Electrocardiograms Using an Interpretable Stacked Deep Learning Model with External Validation.Diagnostics (Basel, Switzerland) · 2026
- Evaluation Protocols and On-Chip Feasibility in Embedded Electrocardiogram Classification: A Systematic ReviewElectronics · 2026
- Deep ECG survival prediction for all-cause mortality under case-mix shift: discrimination, risk underestimation, and recalibrationFrontiers in Cardiovascular Medicine · 2026
- Multimodal Integration of Ambulatory ECG and Clinical Features for Sudden Cardiac Death and Pump Failure Death PredictionmedRxiv · 2026