Prediction of cerebral palsy in extremely preterm infants with beat-to-beat and lower-resolution heart rate variability metrics.
Rathinaswamy B Govindan, Venkata Chaitanya Chirumamilla, Lisa Letzkus, Adre J du Plessis, Karen D Fairchild, Douglas E Lake
Zickler Prenatal Pediatrics Institute, Children's National Medical Center, 111 Michigan Avenue NW, Washington, DC 20010, USA, Washington, District of Columbia, 20010, United States. · The Zickler Family Prenatal Pediatrics Institute, 111 Michigan Ave NW, Washington, 20010, United States.
Key points
From the paper's conclusion- We externally validated that, in preterm infants during the first week after birth, reduced HRV predicts subsequent diagnosis of CP. Measures calculated from btbHR data showed slightly superior performance compared with 1Hz heart rate data displayed on standard NICU bedside monitors.
Abstract
OBJECTIVE: To validate previous findings that low heart rate variability (HRV) in the first week after birth is associated increased risk of cerebral palsy (CP). Additionally, to quantify the extent to which higher resolution beat-to-beat HRV metrics improve CP prediction and determine the effect of heartbeat averaging as done in bedside monitors. APPROACH: For infants <29 weeks gestation at a level IV NICU, beat-to-beat heart rate (btbHR) and corresponding RR intervals (btbRR) from standard monitors were retrieved from a data repository. Monitor-displayed HR based on 12-beat averaging and measured at 1Hz was also collected. The data were segmented into 10-minute windows, and multiple HRV metrics were calculated including standard deviation (SD), low-and high-frequency HRV (LF, HF) and normalized low-and highfrequency HRV (nLF, nHF). Additionally, detrended fluctuation analysis (DFA) slope (alpha) and root mean square (RMS) metrics were calculated for both short (alpha1, RMS1) and long range (alpha2, RMS2) fractal scaling exponents. Metrics were averaged over the first week after birth for each infant to provide representative values that were used to quantify CP prediction performance using the area under the receiver operating characteristic curve (AUC). MAIN RESULTS: This study included 102 infants,11 (10.8%) with CP. The SD of the 1Hz monitor HR had AUC 0.754 compared to the highest values of 0.769 and 0.764 for DFA RMS1 and RMS2. Since raw btbHR contains erroneous beats, averaging generally improves performance. With averaging over 12 beats, as is done by most bedside monitors, RMS2 of btbHR and LF of btbRR had highest AUCs of 0.764 and 0.771 respectively. SIGNIFICANCE: We externally validated that, in preterm infants during the first week after birth, reduced HRV predicts subsequent diagnosis of CP. Measures calculated from btbHR data showed slightly superior performance compared with 1Hz heart rate data displayed on standard NICU bedside monitors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Longitudinal Trajectories of Autonomic Maturation in Preterm Infants Using Serial 24-Hour Heart Rate Variability Monitoring.Biosensors · 2026
- Neurobehavioral stress linked to the central nervous system is associated with heart rate variability differences in preterm infants.American journal of perinatology · 2026
- Heart rate variability after hospital discharge in perinatal risk populations: a systematic review and meta-analysis.Pediatric research · 2026
- Autonomic nervous system maturation in preterm neonates: Correlation with gestational and postmenstrual age (ProMote)PLoS ONE · 2026
- Preoperative Heart Rate Variability and Parasympathetic Modulation in Newborns with Transposition of the Great Arteries Undergoing Arterial Switch Operation.Children (Basel, Switzerland) · 2026
- The Longitudinal Physiological Reference Values of Middle Cerebral Artery Blood Flow Velocity in Extremely Preterm Infants: A Study Utilizing Multimodal Cerebral Hemodynamic Monitors.Children (Basel, Switzerland) · 2026