Synthesis of Multi-Channel Fetal ECG using Generative Modeling.
Swedha Sankaranarayanan, Marta Regis, Judith O E H van Laar, M Beatrijs van der Hout-van der Jagt, Rik Vullings
Electrical Engineering, Eindhoven University of Technology, Groene Loper 3, Eindhoven, Eindhoven, Noord-Brabant, 5612 AE, Netherlands. · Mathematics and Computer Science, Eindhoven University of Technology, Groene Loper 3, Eindhoven, Eindhoven, Noord-Brabant, 5612 AE, Netherlands.
Key points
From the paper's conclusion- We propose a method to address this data scarcity by synthesizing multi-channel fECG signals by modifying inter-beat intervals based on a target fetal heart rate (fHR).
Abstract
Fetal electrocardiography (fECG) provides beat-to-beat cardiac information, offering the potential to improve the assessment of fetal response to uterine activity. However, the accuracy of fECG-derived cardiotocograms (CTGs) depends on signal quality. Scalp electrode recordings offer reliable fECG but are invasive and measurable only during labor. In contrast, non-invasive fECG measurements suffer from a low signal-to-noise ratio and maternal interference. To advance research on the use of non-invasive fECG, there is a need for large datasets with non-invasive multi-channel fECG recorded simultaneously with a clear reference fECG, such as from a scalp electrode. Approach. We propose a method to address this data scarcity by synthesizing multi-channel fECG signals by modifying inter-beat intervals based on a target fetal heart rate (fHR). The proposed method adjusts the duration of the TP segments between consecutive fECG complexes to effectively match the inter-beat intervals of the target fHR. The adjusted multi-channel TP segments are generated by a generative model that has learned the structure of the TP segments in our dataset. The morphology of the fetal QRS complexes remains unchanged. The fidelity of the synthesized signals is evaluated using signal quality indices (SQIs) and fHR estimates. Main results. Most SQIs computed on the input and synthesized signals exhibited strong correlation (r > 0.9), with low mean absolute differences. The error in the standard deviation of the estimated fHR and that of the target fHR was ±3.35 BPM. Morphology-based SQIs exhibited strong correlations (r > 0.9), validating the preservation of fetal QRS complexes. Significance. Our approach generates realistic multi-channel fECG signals that match the target fHR patterns, supporting data augmentation and algorithm development for fetal monitoring. It addresses the scarcity of multi-channel fECG measurements with a clean reference available for algorithm development. It could enhance the robustness of data-driven and source separation methods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- DHF: A Generative AI Approach to Data-Efficient Signal Separation for Wearable Embedded Systems.ACM transactions on embedded computing systems : TECS · 2026
- Advanced detection of fetal arrhythmia utilizing spatial deep convolutional neural network with GHA-DenseNet for enhanced electrocardiographic signal processing.Computer methods in biomechanics and biomedical engineering · 2026
- Flexible framework for generating synthetic electrocardiograms and photoplethysmograms using a parametrized model.Computer methods and programs in biomedicine · 2026
- FHRFormer: a self-supervised masked transformer framework for fetal heart rate time-series inpainting and forecasting.Frontiers in digital health · 2026
- Mode‐specific fetal heart rate signal dropout as a marker of perinatal asphyxia: A multicenter observational study using causal machine learning methodsInternational Journal of Gynecology & Obstetrics · 2026
- Real-time fetal arrhythmia detection using deep learning on an embedded fECG monitoring systemResults in Engineering · 2025