Physics in Medicine & Biology

A scalable data acquisition architecture for multi-gantry long-axial-field-of-view PET systems

Yixing Sun, Yilin Liu, Fei Li, Wei Wang, Weiping Liu, Chao Wang, Xiaojun Chen

Key points

From the paper's conclusion
  • Objective: To develop and evaluate a scalable data acquisition chain (SDAC) for multi-gantry long-axial-field-of-view (LAFOV) PET systems, decoupling lines-of-response (LOR) growth from processing complexity and supporting multiple axial configurations without hardware reconfiguration.
Approach: The SDAC consolidates axial detector data in data combined units (DCUs) prior to centralized coinci

Abstract

Objective: To develop and evaluate a scalable data acquisition chain (SDAC) for multi-gantry long-axial-field-of-view (LAFOV) PET systems, decoupling lines-of-response (LOR) growth from processing complexity and supporting multiple axial configurations without hardware reconfiguration. Approach: The SDAC consolidates axial detector data in data combined units (DCUs) prior to centralized coincidence processing; each DCU applies round-robin arbitration to single events from axially adjacent detector modules and tags every output packet with module and gantry identifiers. The architecture was implemented on a multi-gantry PET platform and evaluated in 2-, 3-, and 4-gantry configurations through count-rate measurements, analytical loss modeling, and an anthropomorphic phantom simulation. Main results: FPGA LUT and Register utilization was reduced by 52% and 63%, respectively, relative to a cross-coincidence implementation. Data loss at peak noise-equivalent count rate ranged from 1.25% (2-gantry) to 3.00% (4-gantry), with linear activity dependence. The analytical data-loss model agreed with measured module counts to within ~0.1%, with no significant activity dependence. In a single-realization XCAT phantom simulation (185 MBq 18F-FDG, four VOIs), count retention ranged from 99.0%–99.2% (Model B) and 96.2%–96.7% (Model C) relative to the no-dead-time baseline. The cross-VOI retention spread was within inter-VOI count-level variability, indicating no position-dependent bias exceeding intrinsic count-level dependence in this simulation; repeated simulations and clinical data are required to establish uniformity under broader activity distributions. Significance: The SDAC enables incremental axial coverage expansion while keeping the coincidence processor unchanged, lowering a practical barrier to LAFOV PET adoption. The analytical data-loss model supports a configuration-independent dead-time correction applicable to the 2–4 gantry configurations validated here, facilitating more practical system-level correction, and is plausibly extensible to higher gantry counts.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers