Influence of pulse shape and coil orientation on TMS activation patterns using biophysical axon models.
Wenzhe He, Ilkka Laakso
Department of Electrical Engineering and Automation, Aalto University, Otakaari 3, Espoo, 02150, Finland.
Key points
From the paper's conclusion- We developed a computational model that combines magnetic resonance image (MRI), white matter tractography, electric field analysis, and biophysical axon models.
Abstract
Despite the clinical prevalence of transcranial magnetic stimulation (TMS), the precise relationship between stimulation parameters and the resulting activation patterns of the axons remains elusive, particularly regarding the interaction between pulse waveforms and coil orientations. Approach. We developed a computational model that combines magnetic resonance image (MRI), white matter tractography, electric field analysis, and biophysical axon models. Using this computational framework, ten publicly available TMS pulse shapes-categorised into monophasic, half-sine, and biphasic waveforms-were evaluated across a 360° range of coil orientations. Focusing specifically on posterior-anterior (PA), anterior-posterior (AP), lateral-medial (LM), and medial-lateral (ML) directions, the model predicted activation intensities and activation sites within the hand area of the primary motor cortex (M1). Main results. Simulated activation intensity ratios matched empirical data from the literature. Excitation using monophasic AP-TMS requires higher electric field intensity compared to PA-TMS. Specifically, AP-TMS activation sites are predicted to be more distal from M1, often occurring in the postcentral gyrus or underneath the central sulcus. Axons are more likely activated under the pulse's negative phase using half sine and biphasic waveforms. Higher threshold is required for activation at LM and ML coil orientations according to model prediction. Significance. Our computational model can be used to generate hypotheses regarding the effect of pulse waveforms and coil orientations against the measurements and observations; and it may assist users to select coil orientations and intensities of TMS for different stimulation targets.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- TMS coil orientation: from computational modeling to experimental evidence and analgesic considerations.Frontiers in neuroscience · 2026
- Optimal pre-experimental coil sequence selection for TMS motor mapping.Imaging neuroscience (Cambridge, Mass.) · 2026
- Spinal Recurrent Inhibition Shapes the Dynamics of TMS-induced Motor-Evoked PotentialsbioRxiv · 2026
- Mapping unintended trigeminal nerve activation during transcranial alternating current stimulation (tACS): A computational study.Journal of neural engineering · 2026
- Mechanisms of transcranial magnetic brain stimulationPhysiological Reviews · 2026
- Pulse waveform and current direction alter network-level TMS-induced functional connectivity: Evidence from TMS-EEGNeuroImage · 2026