NanodosimetricR2model: insights into light-ion-induced DNA-scale damage using human cell survival data.
Mateusz Filipek, Zygmunt Szefliński, Marcin Jan Pietrzak, Beata Brzozowska
Biomedical Physics Division, University of Warsaw, Pasteur 5, Warsaw, 02-093, Poland. · Heavy Ion Laboratory, University of Warsaw, Pasteur 5A, Warsaw, 02-093, Poland.
Key points
From the paper's conclusion- These findings demonstrate that LET alone is insufficient to fully characterise radiation quality, highlighting the importance of explicitly accounting for the spatial distribution of ionisation events.
Abstract
The relationship between radiation track structure and biological effectiveness remains a challenge in radiobiology, particularly for charged-particle therapy. In this work, we present a framework linking nanodosimetric descriptors of ionisation clustering to cellular response. Monte Carlo track-structure simulations using Geant4-DNA were performed for protons, alpha particles and carbon ions over a range of linear energy transfer (LET) values up to 200 keV/µm. The resulting ionisation cluster-size distributions were completed by estimating the zero-ionisation contribution using a dual-GPD model. From the reconstructed distributions, nanodosimetric quantities such as the mean cluster size M1 and the weighted cumulative probability R2 were derived, which account for the combined effect of multiple ionisations on the production of lethal DNA damage. A direct link between nanodosimetry and cell survival data was established through the effective inactivation cross section at 5% survival, derived from a Bayesian-bootstrap estimates of linear-quadratic model parameters for human cell lines. Both analysed parameters M1 and R2 exhibit sensitivity not only to LET but also to particle type. These findings demonstrate that LET alone is insufficient to fully characterise radiation quality, highlighting the importance of explicitly accounting for the spatial distribution of ionisation events. For normal cells, σ5% shows a linear dependence on R2, with a slope interpreted as an effective cross-sectional area of radiosensitive nuclear regions, rather than the geometrical area of the entire nucleus. For tumour cells, variations in radiosensitivity are captured by a single parameter p of R2 model describing the probability of lethal damage accumulation. The cell lines with lower fitted p values (relatively radioresistant) exhibited steeper fitted RBE-LET relationships than those with higher fitted p values (relatively radiosensitive). However, the differences were not statistically significant and should be interpreted as an exploratory finding. The proposed framework provides a physically motivated link between ionisation track structure and biological response. Its potential application to ion-beam treatment planning requires further biological and treatment-plan-level validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of the uncertainty in calculating nanodosimetric quantities due to the use of different interaction cross sections in Monte Carlo track structure codesPLoS ONE · 2026
- Quantifying high-LET heavy-ion-induced non-DSB clustered DNA lesions using Geant4-DNAScientific Reports · 2026
- DNA double-strand break yield and radiation quality of diagnostic X-rays from 40 to 120 kV: a scale-resolved microdosimetric and track-structure studybioRxiv · 2026
- Radiation-Induced Non-DSB Clustered DNA Lesions: Chemistry, Repair, Mutagenesis, and Computational Modeling.Mutation research. Reviews in mutation research · 2026
- AI-assisted quantification of the clonogenic assaybioRxiv · 2026
- A depth-resolved single-flask 3D clonogenic platform for continuous LET-dependent radiobiological assessment in carbon-ion therapy.Physics in medicine and biology · 2026