Multi-beam FLASH-RT preserves skin sparing and reveals novel tissue oxygen dynamics in a murine model.
Corbin Narita, Kevin Jacob Willy, Jason R Gunn, Aleksandra Ilina, David I Hunter, Xu Cao, Petr Bruza, David Gladstone,
Medical Physics, Dartmouth College Thayer School of Engineering, 15 Thayer Dr., Hanover, 03755-8000, United States. · Dartmouth College Thayer School of Engineering, 1 Medical Center Dr., Williamson 7, Lebanon, New Hampshire, 03756, United States.
Key points
From the paper's conclusion- Multiple UHDR beams delivered within five seconds 
provide a statistically indistinguishable degree of normal tissue sparing as a single UHDR beam. 
Furthermore, the observed tissue oxygen dynamics reveal an acute biological response 
potentially unique to UHDR delivery, shedding light on a novel physiological component of the 
FLASH mechanism.
Abstract
OBJECTIVE: The goal of this project was to investigate whether the FLASH skin-sparing effect is preserved across multi-beam ultra-high-dose-rate (UHDR) deliveries and to characterize the accompanying in vivo tissue oxygen dynamics near a 5-second total treatment window previously shown to maintain sparing. APPROACH: Mice were irradiated at three dose levels (23.6, 25.2, and 25.9 Gy) across five experimental groups: single-beam UHDR, two-beam UHDR, six beam UHDR, twelve-beam UHDR, and conventional dose rate (CDR). To evaluate normal tissue toxicity, a skin damage cohort was monitored photographically for four weeks post-irradiation, with acute reactions evaluated by a trained observer. In a separate cohort, real-time tissue oxygenation (pO2) was tracked via a fiber-optic phosphorometer using the phosphorescent probe Oxyphor PtG4 to evaluate physiological kinetics independently of the longitudinal toxicity study. Main results. The FLASH skin-sparing effect was statistically indistinguishable for all experimentally tested UHDR configurations at the 23.6 Gy and 25.2 Gy dose levels. Mixed-effects regression analysis demonstrated that all four UHDR groups developed significantly lower skin toxicity scores compared to the CDR group (p < 0.05). At the highest dose level (25.9 Gy), no significant differences were observed among any radiation groups, which was attributed to a saturation effect of the visual skin score assay at severe damage thresholds. In vivo oximetry showed that tissue oxygen resupply accelerated during UHDR treatment, driven by localized concentration gradients and amplified post-RT by acute biological mechanisms. SIGNIFICANCE: This study represents a promising step toward UHDR multi-beam delivery, a prerequisite for clinical conformal treatment planning. Multiple UHDR beams delivered within five seconds provide a statistically indistinguishable degree of normal tissue sparing as a single UHDR beam. Furthermore, the observed tissue oxygen dynamics reveal an acute biological response potentially unique to UHDR delivery, shedding light on a novel physiological component of the FLASH mechanism.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Data-driven evaluation of quantitative metrics and models for normal-tissue sparing in FLASH radiotherapy.Physics in medicine and biology · 2026
- Fractionation increasingly reduces FLASH sparing for acute murine skin damageRadiotherapy and Oncology · 2025
- Ultra-high-dose-rate pulsed irradiation and the conditional FLASH effect: dosimetry, multiscale biology, and clinical translation.Frontiers in oncology · 2026
- Impact of increased oxygen concentration on the FLASH sparing effect in mice is tissue dependentBritish Journal of Radiology · 2025
- X-ray FLASH: Technologies, evidence and challenges to translation.The British journal of radiology · 2026
- A condensed matter inspired framework for the FLASH effect in radiotherapyMedical Physics · 2026