Physics in medicine and biology

Physics-constrained and geometry-aware deep reconstruction for limited-angle CBCT.

Mingzhe Hu, Shaoyan Pan, Yuan Gao, Huiqiao Xie, Jill Remick, Chih-Wei Chang, Justin Roper, Zhen Tian,

Computer Science and Informatics, Emory University, 400 Dowman Drive, Atlanta, Georgia, 30322, United States. · Department of Radiology Oncology, Emory University, 1365 CLIFTON RD NE, ATLANTA, Atlanta, Georgia, 30322, United States.

Key points

From the paper's conclusion
  • In all three cohorts, PCGA-Net exceeded cGAN and PatRecon-Net across all evaluated metrics. 
Significance: These results indicate that jointly enforcing projection-domain completion, analytic imaging geometry, and image-domain refinement is an effective strategy for limited-angle CBCT reconstruction.

Abstract

Limited-angle cone-beam computed tomography (CBCT) is attractive for imageguided radiotherapy and imaging-guided procedure when full-arc acquisition is impractical, but the incomplete angular sampling leads to severe streaking, shading, and structural distortion. This study aimed to develop a physics-constrained and geometry-aware deep reconstruction framework for recovering anatomically faithful volumetric CBCT from limited-angle projections. Approach: We propose PCGA-Net, a dual-domain reconstruction framework that combines projection completion, analytic geometric reconstruction, and image-domain refinement within a unified cross-domain design. Specifically, a projection completion module first estimates missingangle information from the measured limited-angle projections. A geometry-aware reconstruction module then maps the completed projections into image space using differentiable cone-beam forward and backward-projection operators. Finally, a volumetric refinement module suppresses residual artifacts and restores anatomical detail under geometry-guided cross-domain consistency supervision. The framework was evaluated on three cohorts: gynecologic highdose-rate brachytherapy, abdominal liver 4DCT, and head-and-neck CBCT. Main Results: Across all three cohorts, PCGA-Net consistently outperformed conventional limitedangle FDK reconstruction and the compared learning-based baselines, cGAN and PatRecon-Net, in both qualitative and quantitative evaluation. On the gynecologic HDR brachytherapy cohort, PCGA-Net achieved an MAE of 34.47 ± 6.28 HU, an SSIM of 0.87 ± 0.04, and a PSNR of 35.79 ± 0.95 dB. On the abdominal liver 4DCT cohort, PCGA-Net achieved 39.27 ± 6.10 HU MAE, 0.82 ± 0.03 SSIM, and 36.85 ± 1.16 dB PSNR.On the head-and-neck CBCT cohort, PCGA-Net achieved 28.42 ± 4.88 HU MAE, 0.91 ± 0.05 SSIM, and 38.52 ± 0.95 dB PSNR. In all three cohorts, PCGA-Net exceeded cGAN and PatRecon-Net across all evaluated metrics. Significance: These results indicate that jointly enforcing projection-domain completion, analytic imaging geometry, and image-domain refinement is an effective strategy for limited-angle CBCT reconstruction. PCGA-Net provides a robust short-arc reconstruction framework across multiple anatomical sites, supporting its potential utility in constrained imageguided therapeutic and procedural settings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers