Model-based motion simulation framework for deep learning-assisted motion correction in dynamic wrist CT.
Chunming Gu, Aeden Kayle Davis, Andrew Thoreson, Shengbing Huang, Kevin Treb, Nirusha Lachman, Kristin Zhao, Maryam Sadeghian,
Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, Minnesota, 55905-0002, United States. · Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, 55905-0002, United States.
Key points
From the paper's conclusion- Deep learning (DL)-assisted motion correction has the potential to enhance wrist 4DCT quality, but model development is hindered by scarce training data.
Abstract
Four-dimensional CT (4DCT) enables visualization of dynamic wrist joint pathology but may be compromised by motion artifacts. Deep learning (DL)-assisted motion correction has the potential to enhance wrist 4DCT quality, but model development is hindered by scarce training data. To address this, we developed a model-based motion simulation framework that generated realistic 4DCT data with paired static ground truth images to demonstrate wrist motion correction using a physics-informed DL model trained with simulated data. Approach. Wrist motion was simulated by synchronizing rotational and translational movements of carpal bones and connective tissues. Elastic deformation guided by analytically-derived motion vector fields was applied to static wrist scans at neutral positions to create artifact-free images at multiple angular positions. Virtual motion-corrupted 4DCT images were produced via forward projection and reconstruction with synchronized gantry and wrist motion. Experimental data from 4DCT cadaver scans were collected to validate simulation quality. Low-intensity region score (LIRS), positivity, and entropy were used to assess simulated motion artifacts. A physics-informed motion correction network was adapted exclusively using simulated training data and subsequently deployed on simulated, real cadaveric, and in vivo 4DCT scans. LIRS and structural similarity index (SSIM) were used to evaluate motion correction quality. Wilcoxon signed-rank tests were conducted (α=0.05). Results. The simulation method created realistic motion artifacts compared to real scan reference (p>0.05). Motion artifacts were effectively mitigated across testing cases demonstrating generalizability. In simulated scans, LIRS improved from 0.55±0.12 to 0.75±0.04 and SSIM from 0.87±0.08 to 0.95±0.03 at bone regions (each p<0.01). In experimental cadaveric scans, LIRS improved from 0.05±0.01 to 0.31±0.17 in marker regions and from 0.58±0.19 to 0.77±0.14 in bone regions (each p<0.01). Significance. Our simulation method facilitates training DL-assisted motion correction algorithms by providing high-quality training data, effectively supporting 4DCT image quality enhancement. 
.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of motion quantification in dynamic CT images of the wrist joint across multiple CT vendors: A phantom study.Medical physics · 2026
- Training-free generation of 4D CT and other rare acquisitions improves segmentation across modalitiesmedRxiv · 2026
- Dynamic cone beam CT reconstruction via spatiotemporal Gaussian neural representationMedical Physics · 2025
- Data-driven registration and modeling of brain deformation for image-guided neurosurgery.Medical image analysis · 2026
- BreathSplat: Grounding One Smooth Motion in the Breathing Phase for 4D Cone-Beam CTarXiv · 2026
- Hyperelasticity as an efficient regularizer for 2D-3D thoracic motion modelsarXiv · 2026