Autocalibration signal-guided multi-frequency diffusion model for dynamic MRI reconstruction.
Yu Guan, Wenchao Deng, Qi Qi, Minghui Zhang, Haikun Qi, Xiang Ji, Qiegen Liu
Department of Advanced Manufacturing , Nanchang University, 999 Xuefu Avenue, Nanchang, Jiangxi, 330031, China. · Nanchang University School of Information Engineering, No. 999 Xuefu Avenue, Honggutan District, Nanchang City, Jiangxi Province, Nanchang, 330031, China.
Key points
From the paper's conclusion- The proposed method enables high-quality dynamic MRI reconstruction by exploiting intrinsic ACS information, offering a practical solution without fully-sampled training data.
Abstract
OBJECTIVE: The autocalibration-signal (ACS) region plays a pivotal role in dynamic magnetic resonance imaging (MRI) reconstruction, yet its full potential remains under-exploited in current generative frameworks, which rely mainly on data-driven priors while overlooking ACS-embedded physical information. This work aims to propose a novel multi-frequency aware diffusion model guided by structural priors derived from the ACS region to enhance the quality of dynamic MRI reconstruction. APPROACH: Specifically, the intrinsic phase consistency and spatial smoothness within the ACS region are leveraged to construct a robust prior that stabilizes the diffusion trajectory. This prior further guides the restoration of high-frequency components, thereby improving temporal coherence and structural fidelity.Furthermore, the non-ACS region is divided into two complementary frequency bands, each jointly modeled with the ACS region to establish direction-aware diffusion pathways across the frequency domain. To further refine reconstruction performance, we incorporate low-rank regularization across time frames and enforce data-consistency constraints, which effectively suppress motion artifacts while preserving fine anatomical details. MAIN RESULTS: Quantitative evaluations demonstrate that the proposed method achieves competitive reconstruction quality across various sampling patterns and acceleration factors. Under Radial sampling at an acceleration factor of R=8, it attains PSNR of 32.53±0.34 dB, NMSE of 0.011±0.001 and SSIM of 0.8583±0.057, outperforming all competing methods. Notably, the proposed method achieves competitive performance comparable to supervised models without requiring any fully-sampled data or external training labels. SIGNIFICANCE: The proposed method enables high-quality dynamic MRI reconstruction by exploiting intrinsic ACS information, offering a practical solution without fully-sampled training data.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Adaptive Mask-Guided k-Space Diffusion for Accelerated MRI Reconstruction.Magnetic resonance in medicine · 2026
- Learning Dynamic Affinity Diffusion for Multi-Contrast MRI Super-Resolution via Implicit Neural Representations.NeuroImage · 2026
- A K-space guided invertible diffusion model for accelerating MRI reconstruction.Medical physics · 2026
- Harnessing Magnitude-Only and Complex Measurements for Improved Dynamic MRI Reconstruction with Learned Priors.ArXiv · 2026
- Learning optimized sampling patterns for accelerated MRI reconstruction via diffusion models.Journal of medical imaging (Bellingham, Wash.) · 2026
- SSCA-DIPNet: Structured Sparse and Channel-Attentive Deep Image Prior Network for Highly-Accelerated MRI.Biomedical physics & engineering express · 2026