Artificial count enhancement in lung scintigraphy for acquisition acceleration and pseudo-planar generation.
Amir Jabbarpour, Siraj Ghassel, Sanaz Kaviani, Jochen Lang, Eric Moulton, Ran Klein
Medical Physics, Carleton University, 1125 Colonel By Drive Ottawa, Ontario, K1S 5B6, CANADA, Ottawa, Ontario, K1S 5B6, Canada. · School of Electrical Engineering and Computer Science , University of Ottawa Faculty of Engineering, 800 King Edward Ave, Ottawa, Ontario, K1N 6N5, Canada.
Key points
From the paper's conclusion- In downstream clinical evaluation, this model also yielded superior defect detection performance (sensitivity: 0.800 ± 0.035 at 1.0 false positives per projection), surpassing current clinical practice of the summed angular method.
Significance:
This study introduces the first AI-based framework for generating pseudo-planar lung scintigraphy from low-count data.
Abstract
Ventilation-perfusion (V/Q) planar scintigraphy remains widely used for diagnosing pulmonary embolism (PE), despite the reported superior diagnostic performance of V/Q SPECT. In part, SPECT adoption is limited by the differences in clinical interpretation. Pseudo-planar from SPECT data can facilitate transition to SPECT, but existing methods, such as summed angular projections or forward reprojection, fail to reliably reproduce true planar image characteristics. Approach: We propose a novel artificial intelligence-based count enhancement framework to generate high-fidelity pseudo-planar perfusion images (pQ) from low-count inputs. Two conditional generative adversarial networks (cGANs) were trained using (i) 10% Poisson-resampled planar perfusion images and (ii) matched single-projection SPECT views as inputs, with corresponding full-count planar perfusion images as ground truth. The models were trained and evaluated on 829 paired planar and SPECT studies from a multi-scanner clinical cohort. Performance was assessed using quantitative image similarity metrics (SSIM, PSNR, MSE) and a clinically meaningful task-based evaluation using a previously validated deep learning computer-assisted diagnostic (CAD) model for vascular defect detection via free-response receiver operating characteristic (FROC) analysis. Main results: The cGAN trained on resampled planar images achieved the highest image fidelity (test SSIM: 0.70 ± 0.05; PSNR: 22.3 ± 1.2 dB), significantly outperforming SPECT-trained models and the conventional summed angular method (p < 0.001). In downstream clinical evaluation, this model also yielded superior defect detection performance (sensitivity: 0.800 ± 0.035 at 1.0 false positives per projection), surpassing current clinical practice of the summed angular method. Significance: This study introduces the first AI-based framework for generating pseudo-planar lung scintigraphy from low-count data. The proposed method demonstrates improved image realism and clinically relevant defect preservation, supporting its potential for hybrid planar-SPECT workflows in V/Q imaging and for accelerating acquisition of planar images.
.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial intelligence-enabled detection of vascular perfusion defects on ventilation/perfusion (V/Q) scintigraphy for pulmonary embolism.Physics in medicine and biology · 2026
- Quality-Gated CycleGAN with Frequency-Split Composition for Structure-Constrained Contrast-Like Enhancement of Non-DICOM Chest CT: External Feasibility and Implications for Pulmonary Embolism AI.Bioengineering (Basel, Switzerland) · 2026
- Count-aware diffusion with autoregressive inference for low-count PET reconstruction enhancement.Medical image analysis · 2026
- Ventilation Perfusion Functional Difference Images in Lung SPECT: a linear and symmetrical scale as an alternative to the Ventilation Perfusion RatioarXiv · 2026
- Clinical Implementation of AI for Pulmonary Embolism Detection in over 30 000 CT Pulmonary Angiography ExaminationsRadiology Artificial Intelligence · 2026
- Synthetic CT Pulmonary Angiography From Non-Contrast CT.Journal of imaging informatics in medicine · 2026