Measurement Validation as Scientific Claim Admissibility: An Evidence-Gated Decision Framework

BENAISSA Mohamed, Foued DERRAZ, Sidi Mohammed CHORFI

Key points

From the paper's conclusion
  • The Evidence-Gated Decision Framework implements this operator through applicability resolution, strict non-compensation and a versioned audit trace.

Abstract

Measurement validation is often reported as a binary property of an instrument, although a single system may support some bounded conclusions while leaving stronger ones unsupported. This paper formulates validation as a constrained scientific claim-admissibility problem. A general operator maps declared intended use, evaluated evidence, claim-specific requirements and claim strength to admitted and maximal claims, blocked overclaims, retained limitations, abstentions and next evidence actions. The Evidence-Gated Decision Framework implements this operator through applicability resolution, strict non-compensation and a versioned audit trace. Formal consistency properties establish monotonicity, irredundant evidence bases and local degradation under evidence removal for a frozen model. Measurement uncertainty, traceability and JCGM 106-type conformity decisions remain locally evaluated evidence objects. A synthetic temperature demonstrator isolates the decision logic, while an independent real-data motor-vibration case adds practical evaluation using 24 OROS OR35 acquisitions at four rotational-speed conditions. A magnetically mounted Dytran 3214A2 accelerometer and a Monarch ROS optical tachometer are acquired on the same time base. Across 600, 800, 1000 and 1200 min−1, the absolute group-mean vibration-derived 1×/tachometer frequency differences range from 1.94 × 10−4 to 5.92 × 10−4 Hz, the maximum absolute record-level difference is 0.002408 Hz, and the expanded comparison uncertainties are about 0.0096 Hz (k = 2). The case shows how one local compatibility result supports a bounded frequency-consistency claim without implying traceable acceleration, universal spectral interpretation or field readiness. Seven claim-separable evidence classes are instantiated as EVL 0–6, with EVL 7 reserved for the adjudicated output.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Measurement Validation as Scientific Claim Admissibility: An Evidence-Gated Decision Framework — Science Skim