Determination and optimization of microwave line-of-sight links in mobile base stations based on fiber Bragg grating sensors
İBRAHİM ÖZTÜRK, N. Ozlem Unverdi
Key points
From the paper's conclusion- Overall, the combined time- and frequency-domain analyses provide a more comprehensive characterization of differences in antenna vibration behavior among the investigated orientations.
Abstract
This study investigates the vibration behavior of radio link antennas at different orientations in mobile base stations to support orientation assessment under environmental disturbances. Triaxial fiber Bragg grating (FBG) accelerometers were integrated into the antenna to acquire vibration data at eight orientation angles (0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315°). Each orientation was monitored for five minutes at a sampling rate of 800 Hz. The recorded acceleration signals were analyzed using a moving-window Z-score algorithm for time-domain anomaly detection and Welch power spectral density (PSD) analysis for complementary frequency-domain characterization. The highest overall anomaly ratios were observed at 90° (0.272%) and 135° (0.256%), whereas the lowest ratios occurred at 0° (0.141%) and 45° (0.147%). However, because the orientations were measured sequentially without synchronized on-site meteorological monitoring or independent repeated measurements, the observed differences cannot be attributed exclusively to antenna orientation. A retrospective evaluation of ERA5-Land air temperature data indicated only a limited ambient temperature variation during the measurements; nevertheless, direct sensor-temperature measurements were not available.. PSD analysis revealed recurrent dominant low-frequency components of approximately 2.6–2.8 Hz in the x- and z-axis responses for most orientations, while the y-axis consistently exhibited a dominant high-frequency component around 200 Hz. These results demonstrate that deviations identified by the Z-score can contain distinct spectral characteristics that cannot be distinguished from time-domain anomaly counts alone. The identified spectral components were therefore characterized without attribution to specific physical excitation mechanisms. Overall, the combined time- and frequency-domain analyses provide a more comprehensive characterization of differences in antenna vibration behavior among the investigated orientations. The main contribution is the integration of antenna-mounted triaxial FBG sensors with complementary Z-score and PSD analyses for direct in-situ vibration monitoring and orientation assessment of microwave line-of-sight links under real field conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and Test of a Fiber Bragg Grating Vibration Sensor for a Warning Sign PileSensors · 2026
- Investigation of FBG Accelerometers and Load Sensors for Vibration Analysis and Slip Detection in Robotic Manipulators.Sensors (Basel, Switzerland) · 2026
- Optimized Design of Laser Vibration Measurement Transceiver Optical System for Applications with Rough TargetsPhotonics · 2026
- A Brace-Integrated Fiber Bragg Grating Sensor with a Multi-Hardness Silicone Strain Transfer Substrate for Knee Flexion Monitoring: A Proof-of-Concept Study.Sensors (Basel, Switzerland) · 2026
- Innovative experimental assessment of direct and drive‑by monitoring on two truss bridgesMeasurement · 2026
- Breaking bandwidth limitation: an ESPRIT-assisted microwave photonic interrogation approach for spatially dense FBG sensors.Optics letters · 2026