Effects of alkali-metal deposition on the thermometric performance of YAG:Dy phosphor in a simulated high-alkali combustion environment
Xiaoqi Wang, Yu Huang, Wubin Weng, Peng Ji, Yang Li, Siyu Liu, Yong He, Quanhuan Li,
Key points
From the paper's conclusion- The results show that YAG:Dy ratio thermometry remains reliable only for surfaces whose temperature does not exceed approximately 600 °C.
Abstract
Ash deposition and slagging during high-alkali coal and biomass combustion disturb heat transfer over boiler heating surfaces and can cause localized overheating, making reliable surface-temperature measurement critical. Laser-induced phosphorescence (LIP) thermometry offers fast-response, two-dimensional measurement in harsh combustion environments, but deposited alkali-metal species may alter the optical and thermometric response of phosphor coatings. Here, NaCl and Na2CO3 were deposited onto YAG:Dy coatings in a two-stage tube furnace and a homogeneous burner, and the thermometric response of the exposed coatings was then measured by heating in an electric furnace, with SEM–EDS, phosphorescence spectroscopy, and XRD used to characterize the accompanying changes. Both the 458 nm and 497 nm emissions were progressively attenuated by deposition, becoming pronounced at and above 600 °C and stronger at the higher NaCl loading. Despite this loss of absolute signal, the intensity ratio I458/I497 remained close to that of the original coating below approximately 600 °C and deviated markedly above it, especially after prolonged burner exposure. Emission spectra showed that at 800 °C the fine structure within 450–500 nm was no longer resolved after normalization to the 458 nm band, indicating that exposure altered the relative spectral distribution on which the ratio depends. SEM–EDS showed Na enrichment throughout the analysed regions, and XRD revealed weak additional reflections tentatively consistent with a sodium-containing aluminate phase. The results show that YAG:Dy ratio thermometry remains reliable only for surfaces whose temperature does not exceed approximately 600 °C. Above this range, alkali-induced ratio deviations become substantial and, under severe exposure, the ratio–temperature relation can become non-monotonic, so a measured ratio no longer corresponds to a unique temperature.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of heat-treatment temperature on the optical behavior and luminescence characteristics of Sm₂O₃-doped lithium borate glassesScientific Reports · 2026
- Green-emitting Er3+-doped La3GaO6 phosphors: gel-combustion synthesis, rietveld refinement and photoluminescence properties for solid-state lighting applications.RSC advances · 2026
- Role of Sm3+ ion doping in luminescence and thermal stability performance of LiCdPO4 nanophosphors.Dalton transactions (Cambridge, England : 2003) · 2026
- Yb³⁺ Sensitized Er³⁺ Upconversion Phosphors for Noninvasive Luminescence‐Based Optical ThermometryJournal of the American Ceramic Society · 2026
- Preparation, luminescent properties, and thermal stability of Eu 3+ -doped Na 9 YSi 6 O 18 glass ceramicsJournal of Physics: Conference Series · 2026
- Soft Lattice and Dual-Emitter Engineering in Cr³⁺ -Doped Fluorides: Achieving Highly Sensitive and High-Fidelity Near-Infrared Optical ThermometryInorganic Chemistry · 2026