Capacitive diagnostic sensor embedded in an electrostatic chuck for real-time plasma density measurement
Chang Hee Lee, Jae Hyeon Kim, Hee Sam Cheon, Ji Hwan Kim, In Young Bang, Gwang Ho Lee, Hyo Jong Shin, Yoon Joo Jeong,
Key points
From the paper's conclusion- In addition, real-time comparison between the OES emission intensity and the plasma density measured by the capacitive diagnostic sensor was performed.
Abstract
In plasma processes for semiconductors and displays, the need for real-time diagnostics of plasma conditions for precise process control continues to increase. Consequently, methods that operate in real process gas environments and enable non-invasive diagnostics without affecting plasma characteristics are required. Currently, electrical diagnostic methods, such as Langmuir probes, are used in semiconductor process diagnostics; however, applying these methods in real process gas environments is challenging. Direct exposure to plasma raises concerns about contamination, corrosion, measurement errors due to process interferences, and stability. In this study, we employed a coplanar electrode sensor embedded within an electrostatic chuck to prevent contamination and corrosion. By operating non-invasively within the electrostatic chuck, this sensor enables real-time diagnostics of plasma conditions at the substrate level where the actual process occurs. Plasma density can be determined by measuring the capacitance change induced by the plasma discharge and calculating the corresponding change in charge. Results were compared with measurements using a single Langmuir probe and optical emission spectroscopy. The plasma density measured by the SLP was on average more than 15% higher than that measured by the capacitive diagnostic sensor under different RF power conditions. In addition, real-time comparison between the OES emission intensity and the plasma density measured by the capacitive diagnostic sensor was performed. Plasma was generated in a capacitively coupled plasma structure, and experiments were conducted by applying 13.56-MHz radio-frequency power. The proposed method offers significant implications for improving precision and automation in semiconductor and display fabrication, potentially enhancing production efficiency and quality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Non-invasive plasma monitoring method through dielectric windows using a planar surface wave probePlasma Sources Science and Technology · 2026
- Non-invasive monitoring of process-relevant plasma parameters by Fiber PROES in capacitively coupled Ar/CF 4 plasmasMeasurement Science and Technology · 2026
- Optical cavity-based measurements of electron density in a non-equilibrium atmospheric-pressure plasmaPhysics of Plasmas · 2026
- Dissociative electron attachment dynamics in pulsed Cl2 plasma process: characteristic pulse-OFF time on chamber diameterScientific Reports · 2026
- Multi-diagnostic experimental validation of PIC/MCC simulations of symmetric capacitively coupled plasmas in CF4Plasma Sources Science and Technology · 2026
- Characterisation, Simulation and Optimisation of a Gridless LaB 6 Hollow Cathode DC Plasma Source for Plasma Ion Assisted Electron Beam Deposition of Optical CoatingsJournal of Physics D: Applied Physics · 2026