Measurement Science and Technology

Considering a long reference scale in photogrammetric bundle adjustment for evaluating gravity-induced focal length variation of a VGOS radio telescope

Michael Lösler, Kira-Lynn Kopitzke, Cornelia Eschelbach, Rudiger Haas

Key points

From the paper's conclusion
  • The results show that introducing the long reference scale reduces the volume of the confidence regions of object points by approximately 50 % and significantly decreases parameter correlations, with 68 % of the estimated parameters exhibiting a reduction of at least 50 %.

Abstract

In industrial photogrammetry, the realization of the scale within a bundle adjustment affects the structure of the dispersion matrix of the estimated parameters and, consequently, the precision and reliability of derived quantities. This study investigates the effect of using a scale exceeding the object dimensions instead of several short scale bars. Photogrammetric measurements of a 13.2 m radio telescope were performed at the Onsala Space Observatory to investigate orientation-dependent, gravity-induced changes in the focal length of the main reflector. The data were analysed using a bundle adjustment constrained either by six 1.3 m scale bars or by introducing an additional 14.2 m scale measured in-process with two mobile laser trackers. While thermal expansion corrections were applied to all scales, the long scale could not be observed directly owing to the measurement configuration and therefore had to be realized indirectly. Its realization further required specific orientation-dependent corrections and a rigorous propagation of measurement uncertainties. The results show that introducing the long reference scale reduces the volume of the confidence regions of object points by approximately 50 % and significantly decreases parameter correlations, with 68 % of the estimated parameters exhibiting a reduction of at least 50 %. Furthermore, the mean standard deviation of the estimated focal length is reduced by approximately 150 μm – an improvement of 40 %. The results indicate that extrapolation effects associated with short scale bars are mitigated and long reference scales can substantially improve the precision and reliability of industrial photogrammetry applications in large-volume metrology, even when shorter scale bars provide higher intrinsic distance accuracy. Moreover, the impact of correlations is often underestimated in particular in subsequent applications where results of a prior adjustment are treated as incoming data. The results highlight the importance of accounting for stochastic dependencies in subsequent analyses.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers