Investigations of lead-free multilayer shielding for diagnostic radiology using Monte Carlo simulations.
Mbozeko Mouongue François, Jean Félix Beyala Ateba, Cebastien Joel Guembou Shouop, Bonaventure Mvogo Aloa, Henri Paul Ekobena Fouda
Physics, University of Yaounde I, PO BOX 812, Yaounde, Center, 237, Cameroon. · Radiological Safety and Nuclear Security Authority, Radiological Safety and Nuclear Security Authority, PO BOX 33732, Yaounde, 33732, Cameroon.
Key points
From the paper's conclusion- These results demonstrate the potential of locally available, lead-free composite materials as cost-effective and environmentally sustainable alternatives for radiation shielding in diagnostic radiology facilities while supporting optimisation and ALARA principles.
Abstract
The development of sustainable and lead-free shielding materials is of increasing interest for diagnostic radiology facilities, particularly in low- and middle-income countries where cost, material availability, and environmental considerations are important factors. This study evaluates the radiation shielding performance of fired clay bricks (FCB), concrete, and stainless steel (SS) as alternative structural materials for X-ray facilities operating up to 150 kVp using Monte Carlo simulations with the PHITS code. Mass attenuation coefficients and effective atomic numbers were computed to characterize photon attenuation properties and guide the design of multilayer shielding assemblies. Two concrete-encapsulated assemblies were engineered: a standard composite (C8-FCB200-C8, 2.32 mm lead equivalent) and a steel-reinforced composite (SS2-C8-FCB200-C8, 2.73 lead equivalent). Their performance was benchmarked against a conventional 2 mm lead barrier. Photon flux distributions and effective dose rates (EDR) were evaluated at primary (Cell 20) and secondary (Cells 22, 24, 26) shielding boundaries for X-ray tube potentials ranging from 80 to 150 kVp. At 150 kVp, the lead reference barrier reduced the transmitted EDR to 7.09E-09 µSv/h at the primary barrier and below 1.79E-12 µSv/h at the secondary barriers. A comparative analysis of the EDR recorded behind the alternative barriers reveals that for the secondary barriers, the standard C8-FCB200-C8 configuration was fully adequate across the entire investigated tube voltage range (80 to 150 kVp). Conversely, for the primary barrier, the reinforced SS6-C8-FCB200-C8 composite is strictly required to provide sufficient shielding at 150 kVp. These results demonstrate the potential of locally available, lead-free composite materials as cost-effective and environmentally sustainable alternatives for radiation shielding in diagnostic radiology facilities while supporting optimisation and ALARA principles.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Emerging Sustainable Lead-Free X-ray Shielding Materials: Design Strategies and Future PerspectivesACS Applied Materials & Interfaces · 2026
- Design and shielding effectiveness of adjustable modular medical radiation shelter.Radiation protection dosimetry · 2026
- Evaluation of artisanal red brick as an X-ray shielding material.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Mechanical, Thermal and X-Ray Shielding Properties of Lead-Free Composites of HDPE Filled with Metal-Based PowdersPolymers · 2026
- Development of multilayered polymer-BaSO4 composites for flexible and efficient lead-free X-ray shieldingScientific Reports · 2026
- Calcined Bovine-Bone-Derived Ca-P as a Densification Filler for Tungsten/PVC Lead-Free Flexible X-Ray Shielding Sheets.Polymers · 2026