A microcantilever-based current sensor with magnetic transduction for AC/DC measurement
Kaixiang Zha, Bo Niu, Junyuan Zhao, Yinfang Zhu, Jinchao Li, Yixuan Wang, Jinling Yang
Key points
From the paper's conclusion- A
source-limited 0–2 A DC calibration yields a sensitivity of 141.34 µV/A with 0.81% linearity error.
These results demonstrate that static-strain magnetic transduction enables compact AC/DC current
measurement without resonance-dependent DC recovery.
Abstract
Compact current sensors near distributed loads must resolve both AC and DC components while maintaining electrical isolation, yet cantilever sensors commonly rely on dynamic or resonance-dependent readout. To address this limitation, this work presents a microelectromechanical systems (MEMS) current sensor based on a magnet-integrated piezoresistive microcantilever, AC bridge excitation and digital lock-in amplifier (DLIA) demodulation. A tip-mounted neodymium–iron–boron magnet converts the field gradient of a conductor pair into cantilever loading, and doped-silicon piezoresistors convert the resulting quasi-static stress into a Wheatstone-bridge signal. For the geometry selected by surrogate-assisted optimization, the theoretical bridge-noise-limited force resolution is 2.09 nN over 1–1000 Hz, equivalent to a current resolution of 0.73 mA. Magnet loading shifts the first resonance from 3.34 kHz to 507 Hz, which remains compatible with DC and 50 Hz quasi-static operation. A prototype was characterized over 0–10 A at 50 Hz, giving 0.15% linearity error, 0.38% hysteresis and 0.064% repeatability, and its response remained approximately linear in an extended sweep to 50 A. For DC measurement, the carrier-excited readout gives a root-mean-square bridge-referred noise of 0.114 µV, compared with 0.454 µV for direct low-frequency readout of the same bridge. A source-limited 0–2 A DC calibration yields a sensitivity of 141.34 µV/A with 0.81% linearity error. These results demonstrate that static-strain magnetic transduction enables compact AC/DC current measurement without resonance-dependent DC recovery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biologically motivated magnetic microfluidic rheostats for precise and scalable flow control.Microsystems & nanoengineering · 2026
- Parameter Identification for Magneto‐Mechanical Resonators by a Convolutional Neural NetworkProceedings in Applied Mathematics and Mechanics · 2026
- Parameter Estimation for Model-Based Sensing of Magneto-Mechanical ResonatorsCommunications Physics · 2026
- Continuous Phase-Coherent Readout of a Magneto-Mechanical Resonator Using a Phase-Locked LooparXiv · 2026
- High-Temperature Magnetic Field Mapping Using a Single-Crystal Diamond MEMS Resonator Array.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- MagCilia: A Compact Magnetociliary Tactile Sensor with 3D Force Sensing for Robotic Contact Perception and Grasping FeedbackarXiv · 2026