Microlocal analysis of non-linear artifacts in cone beam CT
James Webber, Alexander Katsevich
Key points
From the paper's conclusion- We present a novel microlocal analysis of beam hardening artifacts arising in cone-beam Xray CT, where the set of X-ray sources is restricted to a 1D smooth curve γ ⊂ R 3 .
Abstract
We present a novel microlocal analysis of beam hardening artifacts arising in cone-beam Xray CT, where the set of X-ray sources is restricted to a 1D smooth curve γ ⊂ R 3 . We show that, when the CT data is modeled in the standard way using the Beer Lambert law, the exponential term in the model creates singularities in the data that are not present in the linear X-ray transform. We assume that the attenuation coefficient µ (the reconstruction target) has a jump discontinuity across a surface S ⊂ R 3 , and is smooth otherwise. We prove that these additional singularities in the data occur when the X-ray beam is tangent to S at two points simultaneously. To investigate how the singularities in the data propagate to the reconstruction space, we apply Filtered Back Projection (FBP) type reconstruction. We prove that the artifacts due to beam hardening are locally of conormal type, and lie on a 2-D surface which is the union of all double tangent rays which intersect γ. The artifacts are notably weaker than the reconstructed jumps of µ (i.e., the desired singularities), and we quantify this using the order of the corresponding conormal distributions. While our primary theory applies to the regions of S that are smooth, we also extend our theory to non-smooth S with "ridges." These arise where S is locally the intersection of two smooth surface patches meeting transversely along a curve (e.g., the edge of a cuboid). In addition, we present simulated reconstructions of metal objects in circular cone-beam CT to validate our theory.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- On microlocal artifacts arising in tomography modeled by a class of generalized Radon transformsInverse Problems · 2026
- Path-length-aware sinogram completion via direct moment enforcement for metal artifact reduction in X-ray CT.Biomedical physics & engineering express · 2026
- Non-circular scan trajectories for reducing cone-beam artifacts in Gamma Knife CBCT images: a simulation studyarXiv · 2026
- CTrex: A Research-Oriented Framework for Kernel- and Projection-Level Algorithm Development in CT ReconstructionarXiv · 2026
- PSF-Informed Reconstruction: An Enhanced 2D Directional Filtered Backprojection Method for Cone-Beam Rotary Computed LaminographyarXiv · 2026
- Cone-beam artifact reduction in Gamma Knife CBCT images using a line-arc-line scan trajectoryarXiv · 2026