Immunological medicine

Evaluation of fluorescein staining with the yellow filter in the diagnosis of Sjögren disease in Japan.

Toshimasa Shimizu, Kazumi Shinozaki, Susumu Nishiyama, Hideki Nakamura, Masafumi Moriyama, Naoto Azuma, Hiroto Tsuboi, Masafumi Uematsu,

Department of Immunology and Rheumatology, Division of Advanced Preventive Medical Sciences, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan. · Sjögren Disease Subgroup, The Research Team for Autoimmune Diseases, The Research Program for Intractable Disease of the Ministry of Health, Labour and Welfare (MHLW), Tokyo, Japan.

Observational · n=400

Key points

From the paper's conclusion
  • After replacing the Rose Bengal test in the 1999 criteria with fluorescein staining with the yellow filter, the modified criteria showed 86.6% sensitivity, 93.6% specificity, and 88.0% accuracy.

Abstract

Sjögren disease (SjD) requires ocular surface assessment during diagnostic evaluation. In Japan, the 1999 revised Japanese Ministry of Health criteria include the van Bijsterveld score based on the Rose Bengal test; however, this test is rarely performed in current clinical practice. Although fluorescein staining with the yellow filter is widely used as an alternative method, its performance for suspected SjD remains unclear. To clinically evaluate this method, this multicenter retrospective study included 400 patients who underwent fluorescein staining with the yellow filter for suspected SjD between 2010 and 2024. Expert clinical diagnosis served as the reference diagnosis, with 322 being diagnosed with SjD and 78 classified as non-SjD. At a cutoff value ≥3 for the van Bijsterveld score using fluorescein staining with the yellow filter, sensitivity was 48.4% and specificity 84.6%, with a positive predictive value of 92.9%. At a cutoff value ≥4, sensitivity was 32.6% and specificity 93.6%, with a positive predictive value of 95.5%. After replacing the Rose Bengal test in the 1999 criteria with fluorescein staining with the yellow filter, the modified criteria showed 86.6% sensitivity, 93.6% specificity, and 88.0% accuracy. Fluorescein staining with the yellow filter may be a practical ocular assessment method for suspected SjD.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers