Expert review of medical devices

Development and validation of an intra-procedural predictive model for radial artery spasm in patients undergoing transradial percutaneous coronary intervention-chronic total occlusion.

Wei Zhang, Zhigang Fan, Lingling Yan, Dong Wang

Cardiovascular Internal Medicine,Rudong People's Hospital, Nantong, China. · Department of Endocrinology, Rudong People's Hospital, Nantong, China.

Observational · n=1,327

Key points

From the paper's conclusion
  • This model is specifically designed for intra-procedural dynamic risk assessment, integrating procedural factors as cumulative risk indicators. External validation is required before routine clinical implementation.

Abstract

BACKGROUND: To develop and internally validate a robust predictive model for radial artery spasm (RAS) to facilitate real-time intra-procedural risk stratification and intraoperative strategy optimization during chronic total occlusion percutaneous coronary intervention (CTO-PCI). RESEARCH DESIGN AND METHODS: This retrospective study analyzed 1,327 patients undergoing CTO-PCI between January 2020 and November 2025. The dataset was divided into a derivation cohort (n = 929) and an internal validation cohort (n = 398) using a 7:3 ratio. Independent risk factors for RAS were identified through multivariate analysis to construct a logistic regression model. Model performance was rigorously assessed via AUC, calibration plots, bootstrap validation with optimism correction, Brier score, calibration slope, and decision curve analysis. RESULTS: Female gender, anxiety status, diabetes mellitus, hyperlipidemia, frequent catheter exchange, multiple radial artery punctures, and prolonged procedure duration were identified as independent predictors of RAS (p < 0.05). Model demonstrated excellent discriminative ability, with optimism-corrected AUCs of 0.974 in derivation cohort and 0.980 in internal validation cohort. Calibration curves, calibration slopes (0.958 and 0.864), and Brier scores (0.048 and 0.035) revealed strong agreement between predicted and observed outcomes. CONCLUSIONS: This model is specifically designed for intra-procedural dynamic risk assessment, integrating procedural factors as cumulative risk indicators. External validation is required before routine clinical implementation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers