Impact of sex, age and inspiratory resistance on perceived breathlessness while wearing an escape respirator.
Dror Ofir, Shir Lerner, Ivan Gur
Israel Naval Medical Institute, IDF Medical Corps, Haifa, Israel. · School of Public Health, Faculty of Social Welfare and Health Sciences, University of Haifa, Haifa, Israel.
Key points
From the paper's conclusion- These findings indicate that inspiratory resistance increases perceived inspiratory breathlessness mainly through mechanical loading rather than clinically meaningful impairment of ventilation or gas exchange.
Abstract
Small increases in inspiratory resistance imposed by escape respirators can elevate the perception of breathlessness. The present study investigated the effects of sex and age on ventilatory responses and perceived breathlessness while breathing through an escape respirator. Forty healthy participants (young males, young females, older males, and older females; n = 10 each) were exposed at rest to three 15 min conditions: no filter, low resistance (7 to 8 mm H2O at a 30 L/min), and high resistance (18.4 mm H2O at a 30 L/min). Minute ventilation (V̇E), tidal volume (VT), breathing frequency (fB), inspired O2 and CO2, transcutaneous CO2, oxygen saturation, and perceived inspiratory and expiratory breathlessness were recorded. Increasing inspiratory resistance produced a clear rise in perceived inspiratory breathlessness, while V̇E, VT, fB, inspired CO2, transcutaneous CO2, and oxygen saturation remained largely unchanged. FIO2 decreased slightly without oxygen desaturation. In the omnibus models, estimates for sex, age, and their interactions were imprecise, and their confidence intervals included zero, although exploratory high-resistance comparisons suggested lower breathlessness in older males and greater discomfort in older females. These findings indicate that inspiratory resistance increases perceived inspiratory breathlessness mainly through mechanical loading rather than clinically meaningful impairment of ventilation or gas exchange. Respirator usability assessment should account for individual variability in perceptual responses to mechanical loading.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Simulated driving is impaired by inspiratory loading with dyspnea in older adultsFrontiers in Rehabilitation Sciences · 2026
- Earlobe Blood Flow Responses to Different Intensities of Inspiratory Resistance Loading in Healthy Young Men.Cureus · 2026
- Assessing respiratory rates and signs of air hunger using the PneumoRator sensor.medRxiv · 2026
- Stimulus-dependent sex differences in dyspnoea: Mechanical loading vs. hypercapnia.Experimental physiology · 2026
- Does the breathing response limit exercise tolerance in patients weaning from mechanical ventilation?ERJ open research · 2026