Characterization of diesel-related pollutant migration in fire stations using low-cost direct-reading monitors.
Ryan Bellacov, Thomas Gerding, Runcheng Fang, Jun Wang, Wei-Wen Hsu
Department of Environmental and Public Health Sciences, College of Medicine, University of Cincinnati, Cincinnati, Ohio. · Department of Biostatistics, Health Informatics and Data Sciences, College of Medicine, University of Cincinnati, Cincinnati, Ohio.
Key points
From the paper's conclusion- These findings indicate that diesel-related pollutant levels in fire stations are influenced by operational and structural factors and support evaluating engineering and ventilation controls to reduce in-station exposure.
Abstract
Fire engines and other vehicles housed within fire stations may generate diesel-related emissions that affect indoor air quality in both engine bays and adjacent occupied areas. This study characterized spatial and daily patterns of selected diesel-related indicator pollutants across three fire stations and evaluated associations between daily engine activity, relative distance from engine exhaust sources, and station characteristics. Multiple direct-reading air quality monitors were deployed at each station for seven consecutive days at fixed monitoring locations representing engine-bay and adjacent occupied spaces. Minute-level measurements of PM10, PM2.5, PM1, NO2, VOCs, and CO2 were aggregated to daily means for statistical analyses. Associations were evaluated using Pearson correlations and hierarchical linear mixed-effects models with restricted maximum likelihood estimation. PM10, NO2, VOCs, and CO2 demonstrated significant associations with selected predictors, including engine activity, source distance, and station (p < 0.05), although the direction and significance of these associations varied by pollutant. PM2.5 and PM1 were not significantly associated with these factors. Measurable pollutant concentrations were detected beyond engine bays, suggesting that pollutants or shared indoor sources may influence adjacent occupied spaces. These findings indicate that diesel-related pollutant levels in fire stations are influenced by operational and structural factors and support evaluating engineering and ventilation controls to reduce in-station exposure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Portable Air Cleaners Are Associated with Low Indoor PM2.5 during the 2025 Los Angeles Wildland-Urban Interface FiresACS ES&T Air · 2026
- Variability and controls of wildfire smoke infiltration in school buildings.NPJ clean air · 2026
- Indoor Exposure to Wildfire Smoke: A Critical Review of Infiltration, Assessment, and RemovalAtmosphere · 2026
- Short-term monitoring of air pollutants at the port-urban exposure zone: a case study of Alexandria Port, Egypt.Environmental monitoring and assessment · 2026
- Evaluation of combustion products in air from electric and internal combustion engine vehicles during full-scale fire experimentsFire Safety Journal · 2025
- Wearable Personal PM 2.5 Monitoring During Wildfire Smoke Episodes in Metro Detroit.medRxiv : the preprint server for health sciences · 2026