Test-retest reliability and agreement of ear-canal and mastoid Wave I Auditory Brainstem Responses in healthy young adults.
Blandine Duval, Jamal Yahiaoui, Francesca Rapido, Laura Breda, Charles Vincent, Cécile Nicoud, Hugo Vanacker, Léa Fougaera-Lempereur,
CILCARE, Montpellier, France. · EuroMov Digital Health in Motion, University of Montpellier, IMT Mines d'Alès, Montpellier, France.
Key points
From the paper's conclusion- Wave I measures show good within-individual reproducibility, supporting longitudinal monitoring. Tester variance was not the dominant source of variability, and the SNR threshold and normalisation approach provide actionable tools for multi-tester studies.
Abstract
OBJECTIVE: This study evaluated the test-retest reliability of Wave I amplitude and latency and examined sources of variability, including head size, cardiac, respiratory parameters and tester effects. Wave I amplitude, a proposed biomarker of cochlear synaptopathy, requires established reproducibility. DESIGN: Thirty participants attended up to four sessions two weeks apart. Click-evoked ABRs were recorded at 80 dB nHL from ear-canal and mastoid electrodes, with ECG monitoring: three sessions by one tester, one by another. STUDY SAMPLE: Adults aged 18-25 years (19 women) with normal audiometric thresholds (Pure-Tone Average 500-4000 Hz < 20 dB HL) and normal speech-in-noise performance (signal-to-noise ratio [SNR] < -3 dB). RESULTS: An SNR-based quality threshold retained >80% of recordings. Reproducibility was higher for Ear-canal than Mastoid recordings (ICC [intraclass correlation coefficient] = 0.80 [95% CI: 0.61-0.88] vs. 0.77 [0.57-0.84]; CV [coefficient of variation] 12-14%). Latency showed excellent agreement (CV 2-3%). Adjusting amplitude for head size and residual noise reduced the central 95% range by 18%, although the distribution remained wide. Tester variance remained below residual within-ear variance. CONCLUSIONS: Wave I measures show good within-individual reproducibility, supporting longitudinal monitoring. Tester variance was not the dominant source of variability, and the SNR threshold and normalisation approach provide actionable tools for multi-tester studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Normative Ranges for Auditory Brainstem Response Wave I Amplitude: A Potential Diagnostic Indicator of Cochlear DeafferentationAmerican Journal of Audiology · 2026
- Label construction can determine measured detector performance on small auditory brainstem response benchmarksFrontiers in Audiology and Otology · 2026
- The Influence of Sex, Ear, and Age on Auditory Brainstem Responses Recorded with the NeuroAudio SystemDiagnostics · 2026
- Evidence for wave-specific effects of click duration on auditory brainstem responses: Modeling and experimental validation.Neuroscience letters · 2026
- Auditory Steady-State Responses in Adults Aged 88-95 Years Measured in a Home Setting: Feasibility and Agreement with Pure-Tone Audiometry.Audiology research · 2026
- Agreement, Reliability, and Measurement Error of Cervical Vestibular Evoked Myogenic Potentials in Patients: II. Meta-Analysis and Reliability of Latency and Amplitude.Ear and hearing · 2026