Evaluating and optimizing retinal examination methods for diagnosing retinopathy of prematurity in premature infants
Tian Liu, Daoman Xiang, Wensi Chen
Guangzhou Women and Children Medical Center
Key points
From the paper's conclusion- Purpose This study aims to evaluate and compare the effectiveness of the Binocular Indirect Ophthalmoscope (BIO) and the Wide-Field Fundus Imaging System (RetCam) in the diagnosis of Retinopathy of Prematurity (ROP).Methods We retrospectively reviewed routinely collected records from a standardized paired-screening workflow for preterm infants examined for ROP in outpatient and inpatient settings
Abstract
Purpose This study aims to evaluate and compare the effectiveness of the Binocular Indirect Ophthalmoscope (BIO) and the Wide-Field Fundus Imaging System (RetCam) in the diagnosis of Retinopathy of Prematurity (ROP).Methods We retrospectively reviewed routinely collected records from a standardized paired-screening workflow for preterm infants examined for ROP in outpatient and inpatient settings during 2020–2021. BIO was performed first by a senior pediatric ophthalmologist, followed within 10 min by RetCam3 imaging by another ophthalmologist. The paired BIO sketches and RetCam images were reviewed by three experienced ophthalmologists, and disagreements were resolved by consensus to establish an adjudicated reference standard for this study. The primary outcome was diagnostic accuracy for ROP zone, stage, plus/pre-plus disease, and lesion extent.Results A total of 796 eyes from 398 preterm infants (birth weight 1323.8 +/− 456.2 g; gestational age 29.8 +/− 2.9 weeks) were examined using both BIO and RetCam. Compared with the adjudicated reference standard, BIO and RetCam achieved AUCs of 0.997 and 0.995 for detecting any ROP, 0.983 and 0.982 for zone classification, and 0.999 and 0.959 for stage classification, respectively. RetCam misdiagnoses were most common in zone III and stage 1 disease. BIO showed lower agreement than RetCam for lesion extent (p < 0.001).Conclusion BIO and RetCam showed complementary strengths in ROP screening. BIO provided clearer peripheral three-dimensional assessment of subtle stage and plus/pre-plus findings, whereas RetCam provided objective wide-field documentation of lesion distribution. A combined strategy may improve diagnostic confidence and clinical management for ROP.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- External validation of an artificial intelligence–based model for retinopathy of prematurity screening using Phoenix ICON retinal imagesJournal of American Association for Pediatric Ophthalmology and Strabismus · 2025
- A Standardized Bedside Screening Protocol for Retinopathy of Prematurity.Journal of visualized experiments : JoVE · 2026
- Image-Based AI for the Diagnosis of Retinopathy of Prematurity: Systematic Review and Meta-Analysis.JMIR medical informatics · 2026
- Refractive Status of Premature and Low-Birth-Weight Babies With or Without Retinopathy of Prematurity at One Year of AgeCureus · 2026
- Automated diagnosis of plus form and early stages of ROP using deep learning modelsScientific Reports · 2026
- Deep Learning Algorithms for the Diagnosis and Staging of Retinopathy of Prematurity: A Systematic Review and Meta-Analysis.Cureus · 2026