Characterizing Heat Health Hazards and Receptivity of Cooling Interventions Among Indoor Lumber Mill Workers in Southern Thailand.
Phayong Thepaksorn, Elizabeth K Hom Thepaksorn, Aaron Bach, Wipawan Kaewlai, Penpitchaya Wongwiwat, Dung Phung
Sirindhorn College of Public Health, Trang, Thailand. · School of Allied Health, Sport and Social Work, Griffith University, Queensland, Australia.
Key points
From the paper's conclusion- Combined cooling strategies can reduce heat strain in indoor industrial settings; however, the adoption of interventions is strongly influenced by practicality and economic considerations. Hybrid approaches and structural improvements are recommended. A full mixed-methods study is needed to evaluate effectiveness, productivity, and cost-effectiveness to inform scalable occupational heat policies.
Abstract
OBJECTIVE: To evaluate the effectiveness and feasibility of two workplace cooling strategies and identify priorities for future mixed-methods research and practical solutions. METHODS: A pilot randomized crossover field trial was conducted among 12 sawmill workers in southern Thailand under three conditions: no cooling (CON), a phase change cooling vest (VEST), and a combined cooling oasis (OASIS: hydration, fans, water dousing, cooling towels). Core temperature and heart rate were continuously monitored. Worker perceptions were explored through post-intervention focus group discussions. RESULTS: Compared with CON, OASIS reduced core temperature (-0.24°C; 95% CI: 0.23, 0.25) and heart rate (-7 bpm; 95% CI: 6, 9), while VEST reduced core temperature (-0.17°C; 95% CI: 0.17, 0.18) and heart rate (-5 bpm; 95% CI: 4, 6). Despite greater physiological benefits from OASIS, most workers preferred VEST due to ease of use and caused minimal disruption to workflow. OASIS was perceived as effective but interruptive. CONCLUSIONS: Combined cooling strategies can reduce heat strain in indoor industrial settings; however, the adoption of interventions is strongly influenced by practicality and economic considerations. Hybrid approaches and structural improvements are recommended. A full mixed-methods study is needed to evaluate effectiveness, productivity, and cost-effectiveness to inform scalable occupational heat policies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Effectiveness of Cooling Vests in Reducing Physiological Strains of Occupational Heat Stress Among Construction Workers.Journal of occupational and environmental medicine · 2026
- Practical and accessible cooling strategies for mitigating exertional hyperthermia in low-resource workplacesTemperature · 2026
- Meta-Analytic Study of Occupational Heat Stress in Healthcare Workers: Scientific Evidence to Guide the Design of Mitigation Strategies.Healthcare (Basel, Switzerland) · 2026
- Mitigating exertional heat illness risk and preserving performance in mass-participation endurance events: a real-world analysis of a graded cooling and fluid replacement strategy.Journal of science and medicine in sport · 2026
- Occupational Heat Stress Prevention Interventions: A Scoping Review of Evidence and Gaps.Journal of occupational health · 2026
- Comparison of Trajectory-Integrated, Stationary, and Wearable Methods for Estimating Thermal Exposure of Factory Workers: Associations Among Thermal Exposure, Fatigue, Thermal Sensation, and Workload.Sensors (Basel, Switzerland) · 2026