Continuous glucose monitoring devices in hospitalized pediatric patients.
Isaiah K Mensah, Christopher W Farnsworth
Department of Pathology and Immunology, Washington University in St. Louis School of Medicine, St. Louis, MO, USA.
Key points
From the paper's conclusion- Therefore, it is imperative to critically assess the accuracy and clinical performance of CGM devices in hospitalized pediatric patients.
Abstract
Continuous glucose monitoring (CGM) has revolutionized the landscape of diabetes management both in adults and pediatrics. CGM devices are now standard-of-care for pediatric diabetes management and are increasingly used in hospitalized patients. In the outpatient setting, studies show increasing analytical and clinical performance of CGM devices with improved diabetes outcomes. However, there are several inpatient factors that impact the accuracy of CGM devices relevant to hospitalized patients. The pediatric population is also the most vulnerable, and changes in management based on a false CGM reading can cause adverse events. Therefore, it is imperative to critically assess the accuracy and clinical performance of CGM devices in hospitalized pediatric patients. In this review, we assess the literature and summarize recent studies on the accuracy of CGM devices in pediatric inpatients, discuss regulatory requirements for their use, safety considerations, and procedures for confirmatory testing using standard-of-care glucose tests.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Guidance for continuous glucose monitor (CGM) use in Canadian hospitals.Canadian journal of diabetes · 2026
- Clinical Implementation of Continuous Glucose Monitoring for Hospitalized Patients: A Position Statement of the Korean Diabetes Association Digital Health Committee.Diabetes & metabolism journal · 2026
- Pediatric Inpatient Continuous Glucose Monitor Accuracy by Sensor Wear Day, Hospital Day, and Glucose Rate of Change.Diabetes technology & therapeutics · 2026
- An International Position Statement on Practical Approaches for Inpatient Continuous Glucose Monitoring, Insulin Pumps, and Automated Insulin Delivery Systems in Adults.Diabetes care · 2026
- Clinical accuracy of Dexcom G6 and G7 continuous glucose monitors in hospitalized pediatric patients with type 1 diabetes: a real-world studyAnnals of Pediatric Endocrinology & Metabolism · 2026
- Inpatient continuous glucose monitoring halves the risk of hypoglycemia in patients with hyperinsulinism.Frontiers in endocrinology · 2026