Lateral Flow Immunoassay Technology for Blood-Based Infection and Sepsis-Related Biomarker Detection: Trends, Analytical Performance, and Clinical Translation.
Riya Thapa, Neeraj Kumar Fuloria, Asif Ahmad Bhat, Nina Varghese, Kamal Narain, Anupam Biswas, Sangita Biswas, Sumita Bhatia,
Faculty of Pharmacy, AIMST University, Bedong, Malaysia. · Faculty of Medicine, AIMST University, Bedong, Malaysia.
Key points
From the paper's conclusion- Clinical translation is dependent on validation using native whole-blood samples, readouts, lot-to-lot quality control, decision thresholds, prospective studies in multiple centers and evidence that LFIA-based testing enhances antimicrobial stewardship and patient care across intensive-care settings.
Abstract
The assessment of infection and sepsis remains challenging because microbiological methods are time-consuming and host-response biomarkers are not sufficiently specific across clinical settings. With its turnaround time, low sample volume, portability and ability to use whole blood, serum and plasma, lateral flow immunoassay (LFIA) provides a viable approach for decentralized measurement. This review examines LFIA platforms for procalcitonin, C-reactive protein, serum amyloid A, interleukin-6, pathogen antigens and multiplex panels. Special focus is placed on colorimetric, time-resolved fluorescence, quantum-dot, chemiluminescent, Raman, electrochemical, and smartphone-based readouts. The performance characteristics are evaluated with respect to analytical parameters, including detection and quantification limits, precision, calibration, and agreement with reference methods. The limitations due to hematocrit, viscosity, anticoagulants, hemolysis, and incomplete plasma separation are considered. There are platforms that demonstrate analytical sensitivity and show agreement with immunoassay platforms, but studies rely on spiked samples, single-centre cohorts, or nontransferable cutoff values. While multiplex formats may enhance biomarker discrimination, they do not resolve differences in concentration ranges or calibration complexity. Clinical translation is dependent on validation using native whole-blood samples, readouts, lot-to-lot quality control, decision thresholds, prospective studies in multiple centers and evidence that LFIA-based testing enhances antimicrobial stewardship and patient care across intensive-care settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Blood-based rapid molecular diagnostics for sepsis: current advances, clinical applications, and future perspectives.Diagnostic microbiology and infectious disease · 2026
- Recent advances in lateral flow immunoassay for virus detection: current achievements, challenges and future prospects.Talanta · 2026
- Point-of-care testing in the diagnosis of infectious diseases.Frontiers in microbiology · 2026
- Analytical and Clinical Evaluation of a Fully Automated Direct-from-Whole-Blood Multiplex PCR Assay Using Large-Volume Reverse Elution for Rapid Bloodstream Infection Diagnosis.Antibiotics (Basel, Switzerland) · 2026
- A-108 Comprehensive Performance Evaluation of a Rapid, Universal, Sepsis Diagnostic Workflow that identifies Pathogens and characterizes their Antimicrobial ResistanceClinical Chemistry · 2026
- Next-Generation Molecular Diagnostics for Sepsis: Toward a SPICE-Based Diagnostic Architecture.Biosensors · 2026