Comparing methods to measure wearable device adherence for physical activity monitoring for persons with autism: A prospective observational cohort study
Melissa Tovin, Sheila B Madden, Kaiwen Wu, Annabel Nunez-Gaunaurd
University of Miami · Nova Southeastern University
Key points
From the paper's conclusion- A prospective observational cohort design was used to compare two methods for determining WD adherence for monitoring PA in adolescents and adults with ASD.
Abstract
INTRODUCTION: Individuals with autism spectrum disorder (ASD) have higher rates of obesity and exhibit more sedentary behaviors than neurotypical peers. Use of wearable devices (WD) to target insufficient physical activity (PA) in this population has increased over the past decade. However, standardized methods for assessing WD adherence remain limited among this understudied population. PURPOSE: A prospective observational cohort design was used to compare two methods for determining WD adherence for monitoring PA in adolescents and adults with ASD. METHODS: Subjects were enrolled in an 8-week telehealth program aimed at improving PA among adolescents and adults with ASD. The Fitbit Inspire 3 WD was utilized for PA tracking and self-monitoring. Subject step activity and heart rate (HR) data were collected for an 8-week period via FITABASE management platform. Adherence was calculated using two methods. Method-A was defined as ≥10-hr daily wear-time based on HR monitoring; Method-B was defined as ≥ 500 steps/day. Observational data collected via researcher field notes documented participant-reported factors and/or behaviors that influenced WD adherence. RESULTS: < .001). Observational data identified disability-related behaviors that negatively impacted Method A derived adherence. CONCLUSIONS: Using HR-based measures of adherence may underestimate device use in individuals with ASD, potentially setting unrealistic expectations for continuous wear. Step-based metrics provides a more inclusive and pragmatic approach for assessing WD adherence in this population, with implications for future intervention design and evaluation. This study highlights the need to tailor WD adherence definitions to the behavioral and sensory profiles of neurodiverse populations. Further study is warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility of Using Consumer-Grade Wearables Among Adolescents Presenting for Specialty Concussion Care: Prospective Longitudinal Cohort Study.JMIR pediatrics and parenting · 2026
- Optimizing accelerometer implementation in a gerotherapeutic trial: Feasibility, adherence, and operational insights of ABLE.PLOS digital health · 2026
- Wearable Biosensors in Youth With Autism With High Behavioral Acuity: Supportive Practices, Acceptability, and the Importance of Nonverbal Signs of Assent to Research Participation.American journal on intellectual and developmental disabilities · 2026
- Remote Assessment of Physical Function and Physical Activity in Adults With Autism Spectrum Disorder: Protocol for Feasibility, Validity, and Reliability Study.JMIR research protocols · 2026
- Electrodermal Activity, Behavior, and Context in Autistic People with High Support Needs: A Retrospective Ecological Study.Healthcare (Basel, Switzerland) · 2026
- Structured physical activity for social communication and repetitive behaviour in children with autism spectrum disorder: a systematic review and exploratory dose-effect meta-regressionBMC Pediatrics · 2026