Repeated-cycle operational response and residual fouling characteristics under NaOCl and vanillin-assisted NaOCl backwashing in membrane bioreactors.
Jihoon Lee, Sungjin Park, Jihyang Kweon, Wonjung Song
Department of Environmental Engineering, Konkuk University, Seoul, Republic of Korea. · Global Institute for Advanced Nanoscience & Technology (GIANT), Changwon National University, Changwon, Republic of Korea.
Key points
From the paper's conclusion- Under vanillin-assisted NaOCl backwashing, total residual carbohydrate and protein were 51.6% and 87.1% of the DI-water values, respectively.
Abstract
Membrane biofouling remains a major operational constraint in membrane bioreactors (MBRs), increasing transmembrane pressure (TMP) and chemical-cleaning demand. This study compared four backwashing conditions-deionized (DI) water, vanillin-only, sodium hypochlorite (NaOCl)-only, and vanillin-assisted NaOCl backwashing - in lab-scale MBRs over an initial baseline filtration period and four post-backwash filtration cycles, using one independent reactor per condition. Although vanillin has been reported to interfere with quorum sensing, no quorum-sensing-related endpoints were measured in this study. Cumulative operation times were 5.7, 6.9, 14.8, and 13.0 d for DI-water, vanillin-only, NaOCl-only, and vanillin-assisted NaOCl backwashing, respectively. NaOCl alone provided the longest cumulative operation and higher operational-time recovery, defined as post-backwash filtration time relative to baseline filtration time, in Cycles I-II. Vanillin-assisted NaOCl backwashing showed numerically higher recovery in Cycles III-IV (Cycle IV: 31.0% versus 17.0%). Endpoint carbohydrate, protein, and biofilm biomass were lowest under NaOCl-only backwashing. Under vanillin-assisted NaOCl backwashing, total residual carbohydrate and protein were 51.6% and 87.1% of the DI-water values, respectively. Carbohydrate was predominantly soluble, while the soluble-carbohydrate concentration remained below the DI-water value. ATR-FTIR spectra showed attenuated protein-associated bands under both NaOCl-containing conditions. NaOCl alone provided the strongest overall cleaning response within the four-cycle test window. Without independent reactor replication, the later-cycle crossover remains a descriptive observation and does not demonstrate a vanillin-specific effect. Replicated, longer-term evaluation with direct measurements of residual chlorine, parent vanillin and its transformation products, and fouling-layer properties is required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Redistribution and increased effluent occurrence of phage-associated antibiotic resistance genes during progressive membrane fouling in lab-scale membrane bioreactors.Journal of hazardous materials · 2026
- Sequential Microcystin-LR Transformation and Adsorption-Assisted Removal by a Reusable Dual-Enzyme Magnetic Biochar Composite.Toxins · 2026
- Exploring the Influence of Quorum Quenching (QQ) on EPS Production and Biofilm Dynamics Across Different Polymeric MembranesPolysaccharides · 2026
- Incorporating Biocarriers in Membrane Bioreactors for Wastewater Treatment and Membrane Fouling Control From a Microbial Perspective.Water environment research : a research publication of the Water Environment Federation · 2026
- Enhanced cleaning strategies for UF/DF membranes in biopharmaceutical downstream processingBioresources and Bioprocessing · 2026
- Microbiome Physiology Response Chip Reveals Enhanced Redox Turnover in Hydrodynamically Cavitated Waste Activated SludgeWater · 2026