Ophthalmic epidemiology

Effect of Pupillary Dilation on Image Gradeability and Diagnostic Performance in AI-Based Diabetic Retinopathy Detection Among Older Adults - A Clinical Evaluation.

Sanil Joseph, Jerrome Selvaraj, Balagiri Sunder, Yueye Wang, Zhuoting Zhu, Xianwen Shang, Kim Ramasamy, Thulasiraj Ravilla,

Ophthalmic Epidemiology Division, Centre for Eye Research Australia Ltd., East Melbourne, Australia. · Research Division, Lions Aravind Institute of Community Ophthalmology, Madurai, India.

Observational · n=100

Key points

From the paper's conclusion
  • Our findings indicate that pupillary dilation significantly improved retinal image gradeability and reduced repeated imaging in older adults. Although diagnostic accuracy metrics remained stable, the higher proportion of gradable images enabled more patients to benefit from AI-assisted DR detection. Selective dilation may therefore be useful when non-mydriatic imaging yields ungradable results, particularly in elderly populations.

Abstract

PURPOSE: Artificial intelligence (AI) has demonstrated significant potential in detecting diabetic retinopathy (DR) from retinal images. However, image acquisition in older adults is often affected by constricted pupils and media opacity. This study evaluated the effect of pupillary dilation on retinal image gradeability and diagnostic yield in AI-assisted DR detection among older adults. METHODS: In this prospective study, adults aged ≥65 years were recruited from a tertiary eye hospital in India. Retinal images were captured using a clinically validated AI-integrated fundus camera (Optain Resolve OPTFC01, Optain Health, Melbourne, Australia) before and after pupillary dilation. The proportion of ungradable images, need for repeated imaging, and diagnostic yield of AI-based DR detection were compared between the two conditions. RESULTS: A total of 197 retinal images from 100 participants (mean (SD) age: 70 (4.78) years) were analysed. Ungradable images significantly decreased from 33% without dilation to 10% after dilation (p < 0.0001). The proportion requiring repeated imaging reduced from 70.6% to 33.5% (p < 0.0001). Before dilation, AI-based DR detection showed a sensitivity of 87.0% (95% CI: 73.7-95.1), a specificity of 88.7% (95% CI: 77.0-95.7), and an AUC of 0.878 (95% CI: 0.813-0.944). Corresponding values after dilation were 86.7%, 86.1%, and 0.864, respectively (p = 0.729). CONCLUSION: Our findings indicate that pupillary dilation significantly improved retinal image gradeability and reduced repeated imaging in older adults. Although diagnostic accuracy metrics remained stable, the higher proportion of gradable images enabled more patients to benefit from AI-assisted DR detection. Selective dilation may therefore be useful when non-mydriatic imaging yields ungradable results, particularly in elderly populations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers