Zipper myopexy for heavy eye syndrome: early outcomes of a modified loop myopexy technique.
Lorenzo Miguel Tranquilino, Alvina Pauline Santiago
Department of Ophthalmology and Visual Sciences, Sentro Oftalmologico Jose Rizal, Philippine General Hospital, University of the Philippines Manila, Manila, Philippines.
Key points
From the paper's conclusion- We report the surgical outcomes of this technique in two patients with heavy eye syndrome.
Abstract
Purpose: Heavy eye syndrome is a restrictive strabismus associated with high axial myopia and displacement of the superior and lateral rectus muscles. Zipper myopexy, recently described by Awadein et al. is a modification of the loop myopexy that approximates the displaced muscles without scleral fixation. We report the surgical outcomes of this technique in two patients with heavy eye syndrome. Methods: Two-patient case series. Results: Two patients with heavy eye syndrome underwent zipper myopexy. Patient A presented with large-angle esotropia and bilateral abduction limitation. Staged bilateral surgery resulted in postoperative hypertropia after the first operation, which decreased following the second operation. Final follow-up demonstrated improved horizontal alignment and abduction. Patient B, who had marked axial elongation, a longstanding blind contralateral eye, and prior strabismus surgery, demonstrated improved horizontal alignment, abduction, and compensatory head posture following surgery. No intraoperative complications were encountered. Conclusion: Zipper myopexy demonstrated favorable early outcomes in these two patients with differing surgical considerations. The improvement in hypertropia following completion of staged surgery in Patient A suggests that bilateral muscle repositioning may help reduce postoperative vertical imbalance. Patient B demonstrates that improved motility may also be achieved despite altered anatomy from previous strabismus surgery and a longstanding blind fellow eye. Zipper myopexy directly addresses superior and lateral rectus displacement through sequential muscle approximation without requiring scleral fixation. The small sample size and short follow-up limit generalizability and assessment of long-term stability, including the risk of recurrent strabismus. Larger studies are needed before routine clinical use can be recommended.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Silicone Band Loop Myopexy for Strabismus Fixus in Heavy Eye Syndrome, Highly Myopic Sagging Eye Syndrome, and Sagging Eye Syndrome.Korean journal of ophthalmology : KJO · 2026
- Heavy eye syndrome in a paediatric patient: an unusual presentation of highly myopic restrictive strabismus.BMJ case reports · 2026
- A case of highly myopic strabismus with large exotropia after Yokoyama procedure.Strabismus · 2026
- Superior oblique weakening as an adjunct to vertical rectus surgery for severe chin-up posture in infantile nystagmus: a case seriesBMC Ophthalmology · 2026
- Two-strip scleral contraction for complex macular and peripapillary retinoschisis in pathologic myopia.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
- Recurrence of Hypertropia in Sagging Eye Syndrome.American journal of ophthalmology · 2026