From the paper's conclusion
  • These findings demonstrate that the synergistic integration of a hemocompatible PU-OLE-PEG layer and a zeolite-containing adsorption layer provides an effective strategy for developing next-generation dialysis membranes with potential applicability in wearable artificial kidney systems.

Abstract

The development of hemodialysis membranes capable of simultaneously achieving efficient toxin removal and excellent hemocompatibility remains a major challenge. In this study, a novel dual-layer nanofibrous dialysis membrane was fabricated by combining a solution-electrospun polyurethane-oleic acid-polyethylene glycol (PU-OLE-PEG) top layer with a melt-electrospun polypropylene/zeolite (PP/Zeo) bottom layer. The PU-OLE-PEG layer was designed to enhance hydrophilicity and blood compatibility, while the PP/Zeo layer provided selective adsorption of uremic toxins. The resulting membranes exhibited a molecular weight cut-off of 22-25 kDa, enabling the selective removal of middle-molecular-weight toxins while retaining essential proteins. The 10PP/Zeo-Zeo-ME-PU-OLE-PEG-SE membrane demonstrated the highest adsorption capacity for creatinine (47 ± 5.3 mg g-1) and removal efficiencies of 58 ± 5.6% for urea, 65 ± 6.5% for creatinine, and 71 ± 6.8% for β2-microglobulin (β2-MG). Under in vitro simulated dialysis conditions, high recovery of bovine serum albumin (BSA, 98 ± 9.5%) was achieved, indicating effective preservation of valuable proteins. Hemocompatibility studies revealed hemolysis ratios below 1%, markedly reduced protein adsorption (0.0023 ± 0.004 mg mL-1), low thrombin-antithrombin complex formation, prolonged activated partial thromboplastin time (35.8 ± 3 s), and minimal platelet adhesion. Furthermore, the membranes exhibited excellent cytocompatibility, with cell viabilities exceeding 90%, favorable cell attachment. These findings demonstrate that the synergistic integration of a hemocompatible PU-OLE-PEG layer and a zeolite-containing adsorption layer provides an effective strategy for developing next-generation dialysis membranes with potential applicability in wearable artificial kidney systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

High-performance and hemocompatible zeolite-modified PP/PU dialysis membranes for uremic toxin removal — Science Skim