Blood pressure variability between radial artery and finger is influenced by haemodynamic factors, age, and insulin resistance.
Manoj Kumar Choudhary, Tuomas Saarinen, Matti Oivo, Johanna Tietäväinen, Antti Tikkakoski, Jukka T Mustonen, Ilkka H Pörsti, Jenni K Koskela
Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland. · Department of Cardiology, Heart Hospital, Tampere University Hospital, Tampere, Finland.
Key points
From the paper's conclusion- High mean arterial pressure is a major factor contributing to greater blood pressure difference between the radial and finger sites. However, the difference is also more pronounced in the presence of lower large artery stiffness, lower pulse pressure amplification, and higher stroke index, older age, and greater insulin resistance.
Abstract
BACKGROUND: In clinical practice, blood pressure (BP) is typically assessed using brachial measurements, whereas finger plethysmography is widely used in vascular physiology research. However, agreement between BP levels at the finger and more proximal sites is not straightforward because of interindividual differences in BP gradients along the arterial tree. METHODS: We investigated factors associated with the mean arterial pressure (MAP) difference between non-invasive radial artery and finger measurements in 574 normotensive and hypertensive individuals without cardiovascular disease, diabetes, or antihypertensive medication. Recordings included pulse wave analysis from radial BP, plethysmographic finger BP, and whole-body impedance cardiography. Radial BP signals were calibrated using oscillometric contralateral brachial artery measurements. RESULTS: Simultaneous mean radial and finger BP (systolic/diastolic) were 131/75 and 122/69 mmHg, respectively (p < 0.001). When examined in quartiles of the radial-finger BP gradient, the average MAP difference was -7, 4, 10, and 20 mmHg, respectively. In linear regression analysis (enter method), a greater MAP difference was significantly associated with higher radial MAP (p < 0.001), age (p = 0.001), and stroke index (p = 0.015); and with lower pulse wave velocity (p < 0.001), pulse pressure amplification (p = 0.002), and insulin sensitivity check index (p = 0.022). CONCLUSIONS: High mean arterial pressure is a major factor contributing to greater blood pressure difference between the radial and finger sites. However, the difference is also more pronounced in the presence of lower large artery stiffness, lower pulse pressure amplification, and higher stroke index, older age, and greater insulin resistance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mean arterial pressure and pulse pressure in relation to cardiovascular disease risk among individuals with diabetes : Exploring cardiovascular risks in individuals with diabetes.BMC endocrine disorders · 2026
- Associations Between Particle Radioactivity and Mean Arterial Pressure Among a Cohort of Older Men.Journal of the American Heart Association · 2026
- Associated factors of elastic and stiffening components of pulse pressure based on 45 517 database of 24 h ambulatory blood pressure monitoring.Journal of human hypertension · 2026
- Average Real Variability Is an Independent Predictor of Increased Arterial Stiffness Assessed by Pulse Wave Velocity.Journal of clinical hypertension (Greenwich, Conn.) · 2026
- Heart rate variability and baroreflex sensitivity derived from finger photoplethysmography during dynamic cerebral autoregulation assessments: Association with age, sex and time of day in healthy volunteers.Physiology international · 2026
- Routine versus standardized blood pressure measurements: Agreement and association with cardiovascular disease.Journal of internal medicine · 2026