Interocular Asymmetry of the Foveal Center Position in Epiretinal Membrane Assessed with En Face Optical Coherence Tomography.

Dmitrii S Maltsev, Alexey N Kulikov, Vera A Zhuravleva

Department of Ophthalmology, Military Medical Academy, St. Petersburg, Russia.

Observational · n=31

Key points

From the paper's conclusion
  • Idiopathic ERM causes functionally significant displacement of the foveal center which can be measured based on assessment of interocular asymmetry of the foveal center position.

Abstract

PURPOSE: To assess interocular asymmetry of the foveal center position in unilateral epiretinal membrane (ERM). METHODS: Healthy individuals and patients with unilateral idiopathic ERM were included in this cross-sectional comparative study. All participants received 12-mm optical coherence tomography angiography (OCTA) scans in both eyes. Interocular asymmetry of the foveal center position was evaluated by superimposing en face structural projections of the right and left eyes, with marked foveal centers and Bruch's membrane opening. The asymmetry of the foveal center position was assessed without and with the compensation of cyclotorsion. The correlation between best-corrected visual acuity (BCVA) and asymmetry of the foveal center position was calculated. RESULTS: The study included 70 healthy volunteers (71.4 ± 12.4 years, 24 males) and 31 patients with unilateral ERM (mean age 70.4 ± 6.4 years, 11 males). In healthy subjects, the mean interocular difference in the foveal center position was 0.31 ± 0.26 mm and 0.11 ± 0.08 mm without and with compensation of cyclotorsion, respectively. In ERM patients the difference was statistically significantly higher, 0.53 ± 0.28 mm and 0.24 ± 0.22 mm, both without and with compensation of cyclotorsion (p < 0.001). Interocular difference > 0.5 mm was statistically significantly more frequent in ERM patients (17/31, 54.8%) than in controls (11/70, 15.7%) (p < 0.05). A statistically significant correlation was observed between difference of the foveal center position and BCVA in ERM-affected eyes, both with (r = 0.65, p = 0.003) and without (r = 0.61, p = 0.004) compensation of cyclotorsion. On multiple regression analysis, foveal center asymmetry remained the only independent predictor of BCVA (β = 0.717, p = 0.010). CONCLUSION: Idiopathic ERM causes functionally significant displacement of the foveal center which can be measured based on assessment of interocular asymmetry of the foveal center position.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers