A New Platform for Investigating Mechanical Contributors to Corneal Endothelial Cell Injury.
Alex J McMullen, Naveen Mysore, Paul D Funkenbusch, Yousuf M Khalifa, Mark R Buckley
Department of Biomedical Engineering, University of Rochester, Rochester, NY, USA. · Flaum Eye Institute, University of Rochester Medical Center, Rochester, NY, USA.
Key points
From the paper's conclusion- We successfully validated that our platform detects differences in CEC viability under different indentation loading conditions. It also revealed a relationship between indentation depth and TCL, suggesting that corneal mechanical properties could serve as a predictor of CEC loss during surgery.
Abstract
PURPOSE: How different mechanical factors contribute to corneal endothelial cell (CEC) loss during eye surgeries remains poorly understood. To begin to address this gap, our objective was to develop an experimental platform capable of detecting differences in CEC viability across different contact indentation loading conditions. METHODS: Corneoscleral rims were dissected from porcine eyes within 72 h after euthanasia. Prior to indentation, endothelia were stained with viability dyes and imaged using fluorescence microscopy. Images were analyzed to determine baseline endothelial z-positions and total/injured CEC counts. Endothelia were then indented under varying conditions, with each of five control factors set to one of two levels using a design of experiments (DOE) strategy. The "high" (+1) level was hypothesized to cause greater CEC loss than the "low" (-1) level. Endothelia were re-imaged/analyzed to calculate indented z-positions and total/injured CEC counts. Total CEC loss (TCL) was defined as the change in percent CEC injury (PCI) plus percent CEC detachment (PCD). The effect of each control factor on TCL, PCI, and PCD was assessed using analysis of means (ANOM) and variance (ANOVA). Z-positions were used to measure indentation depth, and the correlation between indentation depth and TCL was evaluated. RESULTS: The high (+1) level for each control factor resulted in greater TCL, PCI, and PCD than the low (-1) level, although not all effects were statistically significant. Notably, indentation duration had a large and significant effect on CEC viability. The linear regression showed a moderate and significant correlation between indentation depth and TCL. CONCLUSION: We successfully validated that our platform detects differences in CEC viability under different indentation loading conditions. It also revealed a relationship between indentation depth and TCL, suggesting that corneal mechanical properties could serve as a predictor of CEC loss during surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cornealia: automated collective order analysis reveals density-dependent reorganization of donor corneal endotheliumbioRxiv · 2026
- Analysis of clinical factors affecting corneal endothelial cell density in eye bank donors.Frontiers in ophthalmology · 2026
- An Optimized Mechanical Peeling Protocol for Mouse Corneal Endothelium.Bioengineering (Basel, Switzerland) · 2026
- Stability selection machine learning identifies biomechanical markers for subclinical idiopathic corneal endothelial abnormalities.Frontiers in medicine · 2026
- The Effects of Rho-Associated Kinase (ROCK) Inhibitor Supplementation in Corneal Preservation Media for Donor Tissue Used in Descemet's Membrane Endothelial Keratoplasty (DMEK).Cells · 2026
- Long-term corneal endothelial cell loss after paediatric ocular trauma: a specular microscopy study.The British journal of ophthalmology · 2026