Impact of guidewire caliber on biliary cannulation outcomes: a prospective randomized comparison of 0.025-inch and 0.035-inch guidewires.
Alexander Waldthaler, Jeanne Lubbe, Mari Hult, Stefan Linder, Niklas Fagerström, Per Bergenzaun, Urban Arnelo, Erik von Seth
Department of Upper Abdominal Diseases, Karolinska University Hospital, Huddinge, Stockholm, Sweden.
Key points
From the paper's conclusion- The 0.025-inch guidewire is non-inferior to the 0.035-inch guidewire for primary biliary cannulation. Operator experience, not guidewire caliber, was the dominant determinant of primary cannulation success. A specific advantage of the thinner wire in experienced hands is suggested by our data but not established.
Abstract
BACKGROUND AND AIM: Guidewire-assisted biliary cannulation is the standard technique for endoscopic retrograde cholangiopancreatography (ERCP). Whether guidewire caliber influences cannulation success or post-ERCP pancreatitis (PEP) remains uncertain. We evaluated whether the 0.025-inch guidewire is non-inferior to the 0.035-inch guidewire for primary biliary cannulation of the intact papilla. PATIENTS AND METHODS: In this prospective, single-blind, randomized non-inferiority trial, 130 patients with an intact papilla were randomized 1:1 to wire-guided cannulation with a 0.025-inch or 0.035-inch guidewire. The primary outcome was successful biliary cannulation achieved before the ESGE/SADE criteria for difficult cannulation were met, a stricter endpoint than final cannulation success, which was recorded separately. A planned subgroup analysis compared outcomes by endoscopist experience. RESULTS: Primary cannulation success was 47.7% (31/65) with the 0.025-inch wire and 43.1% (28/65) with the 0.035-inch wire, a risk difference of +4.6% (95% CI -12.2 to +21.1; p = 0.73), confirming non-inferiority. Final cannulation success was 96.9% (63/65) in both groups. Cannulation time (335 vs. 420 s; p = 0.74), PEP rate (9.2% vs. 16.9%; p = 0.30), and failed cannulation (3.1% vs. 3.1%) were comparable. Experienced endoscopists achieved higher primary cannulation success with the 0.025-inch wire than fellows (67.9% vs. 32.4%; p = 0.006) and shorter cannulation times (178 vs. 889 s; p = 0.0002), but neither wire was superior within either experience stratum and the wire-by-experience interaction was not significant (p = 0.16). CONCLUSIONS: The 0.025-inch guidewire is non-inferior to the 0.035-inch guidewire for primary biliary cannulation. Operator experience, not guidewire caliber, was the dominant determinant of primary cannulation success. A specific advantage of the thinner wire in experienced hands is suggested by our data but not established.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Efficacy and Safety of a Novel Guidewire for Selective Biliary Cannulation: A Multicenter, Prospective Randomized Controlled StudyThe Korean Journal of Pancreas and Biliary Tract · 2026
- Comparison of the early double-wire technique with the repeat single-wire technique for successful bile duct cannulation: a systematic review and meta-analysis.Clinical endoscopy · 2026
- Difficult biliary cannulation during ERCP: techniques and an evidence-informed practical algorithm.Frontiers in medicine · 2026
- Efficacy and determinants of success in a structured ERCP training program: a retrospective cohort study from a national training center in China.Surgical endoscopy · 2026
- Safety and Efficacy of Primary Needle-Knife Fistulotomy in Patients at High Risk for Post-ERCP Pancreatitis: A Prospective Multicenter Pilot Study Comparing Endoscopists with Different Levels of ERCP and NKF Experience.Digestive diseases and sciences · 2026
- Outcomes of Different Guidewire-Assisted Techniques for Recurrent Malignant Biliary Obstruction After Uncovered Metallic Stent Placement.Journal of digestive diseases · 2026