Functional and gain-based vestibulo-ocular measures across serum 25(OH)D categories: a dissociation between fHIT performance and vHIT gain.
Nazli Akkaya Kurt, Özlem Ertuğrul, Sadiye Murat Acar, Mahmut Tayyar Kalcıoğlu, Alper Köycü
Faculty of Health Sciences, Department of Audiology, Istanbul Gelisim University, Istanbul, Türkiye. · Faculty of Health Sciences, Department of Audiology, Istanbul Medeniyet University, Istanbul, Türkiye.
Key points
From the paper's conclusion- fHIT correct response rates differed for posterior (p = 0.001) and anterior canals (p = 0.019), being lowest at <20 ng/mL; lateral performance was preserved (p = 0.234). All vHIT gains remained within acceptable limits and only anterior canal gain differed (p = 0.001). VEMP latencies were comparable; cVEMP amplitude asymmetry differed (p = 0.023) but opposite to expectation and within normal range.
Abstract
BACKGROUND: Conventional vestibular tests quantify canal and otolith function, whereas the functional head impulse test (fHIT) measures how effectively the vestibulo-ocular reflex stabilizes vision during high-acceleration head motion. Low 25-hydroxyvitamin D [25(OH)D] has been linked to otolith dysfunction, but its relation to functional performance is unknown. OBJECTIVES: To compare otolith, canal and functional measures across serum 25(OH)D categories in adults without overt vestibular disease. MATERIALS AND METHODS: Thirty-nine adults aged 18-65 years with normal hearing were stratified by serum 25(OH)D into three groups of 13 (<20, 20-29.9, ≥30 ng/mL). All underwent audiometry, videonystagmography, cVEMP, oVEMP, vHIT and fHIT. Kruskal-Wallis and Mann-Whitney U tests were used. RESULTS: fHIT correct response rates differed for posterior (p = 0.001) and anterior canals (p = 0.019), being lowest at <20 ng/mL; lateral performance was preserved (p = 0.234). All vHIT gains remained within acceptable limits and only anterior canal gain differed (p = 0.001). VEMP latencies were comparable; cVEMP amplitude asymmetry differed (p = 0.023) but opposite to expectation and within normal range. CONCLUSIONS AND SIGNIFICANCE: Low 25(OH)D was accompanied by reduced functional vestibulo-ocular performance in the vertical canal planes despite normal gains. fHIT may capture subclinical change that vHIT gain does not.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Differences in Left-Right Vestibulo-Ocular Reflex Gain in the Video Head Impulse Test.Journal of clinical medicine · 2026
- High-frequency vestibulo-ocular reflex (VOR) evaluation in patients with spontaneous downbeat nystagmus: a case-control study.Journal of neurology · 2026
- The relationship between vestibulo-ocular reflex gains measured in the suppression head impulse paradigm and physical activity frequencyThe Egyptian Journal of Otolaryngology · 2026
- Optotype duration and head impulse acceleration: a functional approach to vestibulo-ocular reflex assessmentThe Egyptian Journal of Otolaryngology · 2026
- Pooled reference values for the video head impulse test in healthy adults: an observational cross-sectional studyThe Egyptian Journal of Otolaryngology · 2026
- Self-Reported Dizziness Handicap is Related to Functional Capacity in People with Vestibular Hypofunction.Journal of neurologic physical therapy : JNPT · 2026