Results of EAS performed in Japan using long electrodes: a multicenter retrospective survey.
Shin-Ichi Usami, Shin-Ya Nishio, Hidekane Yoshimura, Yutaka Takumi, Kenichi Takano, Shinichi Goto, Chikako Shinkawa, Seiichi Kadowaki,
Department of Hearing Implant Sciences, Shinshu University School of Medicine, Matsumoto, Japan. · Department of Otorhinolaryngology, Shinshu University School of Medicine, Matsumoto, Japan.
Key points
From the paper's conclusion- Preoperative hearing thresholds and age at implantation were comparable between the two surveys. Longer electrodes (FLEX26, FLEX28, or FLEX soft) were used in 68 of 80 ears (85%) in the present survey. Patients implanted with FLEX28 showed slightly poorer hearing preservation than those implanted with FLEX24; however, the difference was not statistically significant.
Abstract
BACKGROUND: Electric-acoustic stimulation (EAS) has become an established treatment option for patients with high-frequency hearing loss. In Japan, all FLEX electrodes were approved for EAS in August 2023, resulting in increased use of longer electrodes. AIMS/OBJECTIVES: We investigated the impact of this approval on patient selection and electrode choice for EAS and compared hearing preservation outcomes between longer electrodes and FLEX24. MATERIALS AND METHODS: We retrospectively reviewed 68 EAS cases (80 ears) treated at 27 centers in Japan from August 2023 to October 2025 and compared the findings with those from 55 EAS cases using FLEX24 in a post-marketing survey conducted at 20 centers between 2014 and 2016. RESULTS: Preoperative hearing thresholds and age at implantation were comparable between the two surveys. Longer electrodes (FLEX26, FLEX28, or FLEX soft) were used in 68 of 80 ears (85%) in the present survey. Patients implanted with FLEX28 showed slightly poorer hearing preservation than those implanted with FLEX24; however, the difference was not statistically significant. CONCLUSIONS AND SIGNIFICANCE: Sufficient residual hearing was preserved even with longer electrodes. These findings support the increasing use of longer electrodes for EAS to provide adequate cochlear coverage while accommodating potential future deterioration in hearing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Initial High-Frequency Amplification Accuracy Predicts Long-Term Hearing Aid Fitting Outcomes: A Real Ear Measurement-Based Study.Journal of clinical medicine · 2026
- Extracochlear Electric Stimulation - Toward Non-Invasive Hearing RestorationbioRxiv · 2026
- The incremental contribution of extended high-frequency thresholds to speech-in-noise performance.Hearing research · 2026
- Extended High-Frequency Audiometric Characteristics in Patients With Meniere's Disease: A Retrospective Cross-Sectional Study.Ear, nose, & throat journal · 2026
- Acoustic Masking of Electric Stimulation at Basal and Extra-Cochlear SitesbioRxiv · 2026
- Point-of-care hearing screening using consumer wireless earbuds in patients with USH2A-associated retinal disease: a prospective pilot feasibility studyScientific Reports · 2026