Optimising cinefluoroscopy for accurate evaluation of mechanical prosthetic valves
Arda Güler, Busra Kuru Gorgulu, Dilara Pay, Kadir Sadıkoğlu, Mehmet Çiçek, Sezgin Atmaca, Gizem Nur Coşkun, Bahar Zeynep Cetin,
Burdur Mehmet Akif Ersoy Üniversitesi · Bahçeşehir University
Key points
From the paper's conclusion- This study demonstrates that CF is an effective imaging modality for mechanical PHVs when appropriate positioning and projection angles are used.
Abstract
BACKGROUND: Accurate assessment of mechanical prosthetic heart valves (PHVs) is essential to ensure proper function and long-term durability. Cinefluoroscopy (CF) enables real-time visualisation of valve leaflet motion but relies heavily on optimal projection angles for diagnostic accuracy. This study aimed to optimise CF imaging parameters to improve the reliability and precision of PHV evaluation. METHODS: Between October 2021 and June 2024, 262 patients with mechanical aortic or mitral PHVs underwent CF evaluation based on clinical or echocardiographic indications. Valve motion was evaluated across multiple patient positions (supine, right and left lateral decubitus) and C-arm projections. Imaging was considered optimal when the X-ray beam was perpendicular to the valve plane, allowing accurate visualisation of leaflet motion. If optimal imaging could not be achieved across all standard views, it was classified as non-optimal. RESULTS: A total of 331 mechanical PHVs were evaluated, including 250 aortic and 81 mitral prostheses. Optimal imaging was achieved in 94.8% of aortic and 66.7% of mitral valves. The supine position yielded the best visualisation in both groups (87.8% for aortic, 61.1% for mitral). The most frequent optimal projection was left anterior oblique-cranial for aortic valves and right anterior oblique-cranial for mitral valves. CONCLUSIONS: This study demonstrates that CF is an effective imaging modality for mechanical PHVs when appropriate positioning and projection angles are used. Optimal imaging is more readily achieved in aortic valves, while mitral valves require a more tailored approach due to anatomical constraints. Standardising imaging techniques may improve diagnostic accuracy and reduce radiation exposure in clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- FP12.7 Imageless Navigation in Hip Resurfacing Arthroplasty: Accuracy of Cup Positioning and Leg Length RestorationJournal of Hip Preservation Surgery · 2026
- Modified fourth-generation minimally invasive technique with a modified K-wire fixation technique for hallux valgus: a biomechanical and clinical study.BMC musculoskeletal disorders · 2026
- Scissors-Based Leaflet Modification to Prevent Coronary Obstruction in Valve-in-Valve Transcatheter Aortic Valve Replacement: The EXCALIBUR Technique-A Case Report.Journal of the Society for Cardiovascular Angiography & Interventions · 2026
- ConRef: Auditing Reference Reliability in 2D/3D Registration BenchmarksarXiv · 2026
- Automated intraoperative segmentation and path planning framework for femoral neck fractures under fluoroscopic guidanceJournal of King Saud University Computer and Information Sciences · 2026
- Ultra-high-resolution Photon-Counting CT for Leaflet-Specific Evaluation of Fibrosis and Calcification in Aortic StenosismedRxiv · 2026