Current problems in diagnostic radiology

Radiology-led 3D printing in adult cardiothoracic care: a narrative review and implementation roadmap.

Farbod Khosravi, Adarsh Somayaji, David Traina, Hamid Chalian

Department of Radiology, Cardiothoracic Imaging Section, University of Washington, Seattle, WA, USA. · Clinical Additive Manufacturing Program (CAMP), Division of Healthcare Simulation Science, Department of Surgery, University of Washington, Seattle, WA, USA.

Review

Key points

From the paper's conclusion
  • This narrative review combines appropriateness criteria, a structured update of comparative studies published since November 2019, implementation and quality literature, and U.S. regulatory and coding sources into a radiology-led roadmap for adult acquired cardiac, thoracic aortic, and thoracic care.

Abstract

Patient-specific three-dimensional (3D) printing can help plan selected cardiothoracic procedures, but print accuracy alone does not make a model useful. This narrative review combines appropriateness criteria, a structured update of comparative studies published since November 2019, implementation and quality literature, and U.S. regulatory and coding sources into a radiology-led roadmap for adult acquired cardiac, thoracic aortic, and thoracic care. For left atrial appendage occlusion, meta-analyses of small comparative studies associate printed models with fewer device-size disagreements and peri-device leaks. For transcatheter valve procedures the evidence is mostly feasibility and accuracy work, and for septal myectomy, thoracic aortic repair, and lung segmentectomy it is largely single-center and retrospective; the only randomized trial that kept digital reconstruction in both arms found no difference. Digital planning, including virtual reality and computational simulation, is therefore the comparator against which printing should be judged. The 10-step pathway runs from the clinical question and a documented print-or-no-print decision through imaging and model prescription, segmentation, anatomic validation, design approval, manufacture, verification and release, delivery, and outcome tracking. We map published accuracy data to verification targets, follow an illustrative case through every step, and set out why radiology should own the image-dependent steps, what that costs, and which alternative service models exist. Controls are scaled to three operational categories that are not regulatory device classes. Prospective comparisons with contemporary digital planning, reporting failures and denominators, are still needed.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers