Current problems in diagnostic radiology

CT esophagram: is it really as good as we think?

Olivia F Lane, Tae Joon Kim, Brian W Bresnahan, Charles Watt, Daniel S Hippe, Jonathan R Medverd, Puneet Bhargava

Department of Radiology, University of Washington, 1959 NE Pacific Street, Seattle, WA, 98195, United States. Electronic address: oflane@uw.edu. · Department of Radiology, University of Washington, 1959 NE Pacific Street, Seattle, WA, 98195, United States.

Computational

Key points

From the paper's conclusion
  • CT esophagram demonstrated high diagnostic performance, supporting its use as an alternative when fluoroscopic esophagram is not readily available. These findings support after-hours CT-based imaging pathways while emphasizing the importance of selective additional evaluation in high-risk patients and standardized institutional imaging protocols.

Abstract

PURPOSE: To evaluate the diagnostic performance and safety of computed tomography (CT) esophagram for suspected esophageal perforation or leak, with emphasis on after-hours utilization, clinical risk stratification, and institutional imaging workflows. METHODS: This retrospective quality assurance review included 314 CT esophagram examinations performed at a large academic medical center between January 2021 and January 2026. Diagnostic performance was assessed through clinical outcomes and follow-up diagnostic testing, stratified by pretest risk and timing of interpretation. Institutional imaging practices were compared with those of six peer academic medical centers. RESULTS: Overall sensitivity was 94.4% (34/36), specificity was 95.7% (266/278), and negative predictive value was 99.3% (266/268). After-hours examinations demonstrated 100% sensitivity (15/15) and 94.3% specificity (100/106), without statistically significant differences compared with business-hours examinations (p = 0.50 and p = 0.38, respectively). No esophageal injuries were identified among 48 low-risk examinations. External benchmarking demonstrated substantial variability in imaging workflows, with CT esophagram frequently used when fluoroscopic esophagram was unavailable after hours. CONCLUSION: CT esophagram demonstrated high diagnostic performance, supporting its use as an alternative when fluoroscopic esophagram is not readily available. These findings support after-hours CT-based imaging pathways while emphasizing the importance of selective additional evaluation in high-risk patients and standardized institutional imaging protocols.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers