Physics of Fluids

Role of step height in aeration performance over a pre-aerated stepped spillway

Jingyi Zhang, Yinhui Zhang, Yang Chen, Shanjun Liu, Ruidi Bai

Key points

From the paper's conclusion
  • These findings demonstrate that a larger step height promotes the formation of a denser layer of fine bubbles near the chute bottom, thereby improving cavitation protection.

Abstract

This experimental study investigates the effect of step height on the air–water flow properties in a stepped spillway equipped with an upstream aerator ramp. Physical model tests were conducted on a 30° sloping chute with three step heights (0.025, 0.05, and 0.1 m). A double-tip conductivity probe was used to measure the air concentration, bubble frequency, and bubble chord length. The results show that increasing step height increases both the near-bottom air concentration and the cross-sectional mean air concentration. A larger step height also enhances bubble breakup, leading to a higher proportion of small bubbles and an increase in bubble frequency. These findings demonstrate that a larger step height promotes the formation of a denser layer of fine bubbles near the chute bottom, thereby improving cavitation protection.

Read the paper