APL Quantum

Coherent-response and thermal-fluctuation information in cavity-magnon magnetometry

Guogan Zhao, Xiao-Feng Qian

Key points

From the paper's conclusion
  • These results establish a measurement-specific metrological framework and provide distinct operating rules for exploiting coherent response, thermal fluctuations, or both in cavity–magnon magnetometry.

Abstract

Magnetic sensing with cavity–magnon systems is commonly optimized through coherent response functions, while field-dependent fluctuations are treated primarily as measurement noise. Here, we show that this description omits a distinct and experimentally accessible source of magnetic-field information: the field dependence of the measured quadrature variance. For repeated phase-sensitive measurements of a calibrated microwave quadrature, we derive the complete Gaussian likelihood and demonstrate that its Fisher information separates exactly into a coherent-displacement contribution, determined by the field derivative of the quadrature mean, and a thermal-fluctuation contribution, determined by the field derivative of its variance. The two contributions arise from the same measurement record but obey different optimization principles. For the amplitude quadrature, the dimensionless coherent morphology is globally maximized at cooperativity C = 2, corresponding to coupling strength g=2κaκm, and at linewidth-normalized detunings δa = δm = ±1. With a near-resonance expansion, the reduced variance-information is globally maximized at cavity-magnon absolute-detuning matching, Δa = Δm, and approaches a finite large-cooperativity limit. The competing nature of the two sources of contribution is shown in detail under all parameter regions of driving frequency and temperature. Most notably, thermal variance contribution remains finite when coherent driving information is buried in noise (e.g., at low-temperature and low-excitation cases) or even vanishes. It reveals that thermal fluctuations can carry operational magnetic-field information even when the coherent-displacement contribution is unobservable or absent. These results establish a measurement-specific metrological framework and provide distinct operating rules for exploiting coherent response, thermal fluctuations, or both in cavity–magnon magnetometry.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Coherent-response and thermal-fluctuation information in cavity-magnon magnetometry — Science Skim