Standoff detection of carbon monoxide from the underground high explosive detonation in Physics Experiment 1-A using swept-wavelength ECQCL spectroscopy
Mark C. Phillips, Bruce E. Bernacki, S. S. Harilal, the PE1 Experiment Team
Key points
From the paper's conclusion- The results showed that CO detected above ambient levels throughout most of this period, with a 5 orders-of-magnitude measurement dynamic range.
Abstract
Results are presented from a custom-built standoff infrared spectroscopy instrument used to detect above-ground CO generated in the Physics Experiment 1-A test, in which 13 580 kg of high explosives were detonated in an enclosed underground chamber. The instrument used a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) scanned over a wavenumber (wavelength) region of 1965–2290 cm−1 (4.37–5.09 μm) at a 100 Hz rate. The system was configured for standoff open-path measurements with a 223 m distance between the swept-ECQCL instrument and a retro-reflecting mirror, with the beam passing directly above a vent connected to the underground tunnel complex containing the detonation. Spectral fitting provided column densities of CO, CO2, H2O, and N2O, and a spectroscopic temperature, at 1 s intervals over a continuous 27-day period after detonation. The results showed that CO detected above ambient levels throughout most of this period, with a 5 orders-of-magnitude measurement dynamic range. Statistical analysis of the time-resolved CO signal shows a large fraction of low-magnitude and short-duration CO plume fluctuations. Measurement precision/sensitivity for CO detection is characterized to be 0.20 ppm × m at 1 s averaging, improving to 0.05 ppm × m when averaged to 100 s, corresponding to average CO concentrations of 450 ppt at 1 s and 110 ppt at 100 s. The combination of continuous high-speed measurements at high-precision and with high dynamic range provided by the swept-ECQCL sensor provides a valuable capability for detection and characterization of transient plume sources released into the atmosphere.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Self-mixing detection of methane and carbon dioxide using mid-infrared quantum cascade lasersSpectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · 2026
- Ultra-Wide-Range Online Monitoring of Carbon Dioxide Based on a Dual-QTF Photoacoustic Spectroscopy SensorAnalytical Chemistry · 2026
- Sub-shot-noise infrared gas concentration sensing via coincidence detection of quantum-correlated photons.Optics letters · 2026
- Long-wavelength QCL spectrometer for the detection of CO2, C6H6 and C2H2 at the ppb-level.Optics express · 2026
- External cavity quantum cascade laser absorption spectroscopy based on convolutional neural network algorithm for volatile organic compounds analysis.The Review of scientific instruments · 2026
- Dual-band scanned-wavelength infrared laser-induced fluorescence of CO with time-domain modeling for 1 kHz thermometry.Optics express · 2026