A viscosity-adaptive valveless piezoelectric pump for in vitro debridement
Bohai Dong, Lipeng He
Key points
From the paper's conclusion- These results demonstrate that the proposed pump maintains relatively stable flow under varying viscosities and provides effective contaminant removal under simulated wound-irrigation conditions, highlighting its potential for clinical wound-irrigation devices.
Abstract
Valveless piezoelectric pumps offer a compact structure, fast response, and flexible flow regulation, showing promise for portable wound irrigation and debridement devices. However, their viscosity adaptability and debridement performance have rarely been evaluated together, limiting practical application. This study proposes a viscosity-adaptive valveless piezoelectric pump for in vitro wound debridement and compares its performance with a commonly used peristaltic pump. When viscosity increased from 1.0 to 19.0 mPa s, the flow attenuation rate of the piezoelectric pump was 22.7%, lower than the 34.0% of the peristaltic pump. An in vitro cleaning platform consisting of an agar substrate and a carboxymethyl cellulose sodium/activated-carbon-simulated adhesive contamination layer was further established to compare the two pumps at identical average flow rates. Quantitative image analysis showed that the piezoelectric pump consistently achieved lower residual contaminant area ratios at 90, 110, and 130 ml/min. At 110 ml/min, the residual ratios were 1.249% and 5.387% for the piezoelectric and peristaltic pumps, respectively. These results demonstrate that the proposed pump maintains relatively stable flow under varying viscosities and provides effective contaminant removal under simulated wound-irrigation conditions, highlighting its potential for clinical wound-irrigation devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Research on the output performance of valve-less piezoelectric pump with asymmetric composite drainage structuresEngineering Research Express · 2026
- A piezoelectric pump with flow-concentrating chamber for multifunctional microfluidic systems.Mikrochimica acta · 2026
- A Tunable Flat-Jet Hydro-Debridement Device: Clinical Feasibility for Soft Tissue Wound ManagementmedRxiv · 2026
- Autonomous paper valves using PDMS vacuum pumps as actuators for colorimetric chrono-sampling.Lab on a chip · 2026
- Cyclic Fouling and Flux Recovery in a Piezoelectrically Actuated Polytetrafluoroethylene Membrane Module.Membranes · 2026
- A microfluidic vacuum-pressure-driven device for liquid viscosity measurementScientific Reports · 2026