The inverse capillary-rise problem: Conditioning, resolution limits, and the comparability of contact angles
Hesham Jaber Alnoor, Amir Hossein Saeedi Dehaghani
Key points
From the paper's conclusion- We show that it is intrinsically ill-conditioned near complete wetting, derive a closed-form uncertainty for the inferred angle, and use it to determine a resolution floor, below which an apparatus can report only an upper bound, and an optimal tube radius.
Abstract
The height to which a liquid rises in a capillary tube depends on its surface tension and on its contact angle with the wall. Computing the height from a known angle, the forward problem, has been settled for a century: the meniscus-volume correction (r/3)M(θ) is due to Verschaffelt and Dorsey. The relation is now routinely used in reverse, with the surface tension taken from a table and the contact angle inferred from the measured height, but this inverse problem has not been analyzed. We show that it is intrinsically ill-conditioned near complete wetting, derive a closed-form uncertainty for the inferred angle, and use it to determine a resolution floor, below which an apparatus can report only an upper bound, and an optimal tube radius. For water, the floor is 3°–5°, and better length metrology cannot lower it, because the reference surface tension contributes 60%–97% of the variance and the rise height less than 2%. Because authors invert different meniscus treatments, two laboratories measuring the same surface with different tubes can report angles differing by 5° with no experimental error, and the discrepancy grows with radius, mimicking a confinement effect. Re-inferring traceable published values shifts them by up to 6°, and three of eleven admit no solution at all. Benchmarking six treatments against an eleven-point historical dataset identifies Verschaffelt's forgotten second-order term as the most accurate closed form; length and volume observables such as the meniscus height or the footprint of a sessile drop remain well conditioned where the column weight fails.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Correcting a capillary-number sign pitfall in Kistler dynamic contact-angle modeling of droplet/bubble recoil and receding contact linePhysics of Fluids · 2026
- Capillary forces between two identical spherical particlesarXiv · 2026
- Refinement of the added mass coefficient in capillary rise dynamicsJournal of Engineering Mathematics · 2026
- PANDA-D: Interface-free determination of two dynamic contact anglesarXiv · 2026
- RAISE-Vision: An Automated Contact Angle Measurement Platform for Contact Lens Wettability CharacterizationarXiv · 2026
- Observation-scale dependence of apparent dynamic contact angle in droplet impact on a hydrophilic silicon wafer surfaceScientific Reports · 2026