Effect of recirculation-zone regulation on vibration and energy conversion in a double-interference piezoelectric energy harvester
Haochen Tian, Rundai Cui, Huifang Jin, Yanchang Sun, Shuang Wu, Derong Duan
Key points
From the paper's conclusion- Thus, the maximum recirculation zone vorticity increased by 150% compared with the baseline, resulting in a maximum displacement of 40.68 mm with a 7.5% improvement over the baseline case.
Abstract
In wake-induced vibration piezoelectric energy harvesting, the recirculation zone was a critical factor governing wake structure and flow excitation. To reveal the mechanism by which downstream interference column spacing regulates the recirculation zone, wind tunnel tests and two-way fluid–structure interaction simulations were conducted to investigate the influence of recirculation-zone regulation on wake-induced response and output performance. Results demonstrated that the feedback effect of the downstream interference column on the responsive cylinder first increased and then decreased with increasing spacing ratio in the range of 3.5–5.5. At a spacing ratio of 3.5, the maximum vorticity in the recirculation zone increased by 100% compared with the baseline case, because the shorter cylinder gap reduced vortex dissipation during backflow and generated weak gap thrust. When the spacing ratio was 4.5, the moderate cylinder gap enabled full vortex development and minimal dissipation. Thus, the maximum recirculation zone vorticity increased by 150% compared with the baseline, resulting in a maximum displacement of 40.68 mm with a 7.5% improvement over the baseline case. At a spacing ratio of 5.5, the vortices dissipated prematurely and disrupted wake symmetry, generating a displacement 8.7% lower than that of the baseline configuration. As a result, the maximum output voltage 1.18 V was obtained at G* = 4.5 with a 4.4% improvement over the baseline case, while the minimum output voltage was 1.04 V at G* = 5.5 with a 8.7% reduction. This study verified the modulation mechanism of downstream cylinder spacing on the recirculation zone, offering theoretical support for optimization and application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Wind tunnel experiments on flow-induced vibration and energy harvesting: Vibrating and stationary cylinder interactionsResults in Engineering · 2025
- Coupled effects of center-of-gravity position and added mass on vortex-induced vibration and galloping-based hydrokinetic piezoelectric energy harvestingApplied Physics Letters · 2026
- Numerical and experimental investigation on a novel wake galloping piezoelectric energy harvester with adjustable angle of attackSmart Materials and Structures · 2026
- Numerical investigation of enhanced vortex induced vibration energy harvesting of a circular cylinder using a rotating control rodPhysics of Fluids · 2026
- Enhancing wind energy harvesting performance by leveraging the synergy of rotational and transverse wake galloping mechanismsEnergy · 2025
- Analysis and optimization of single and tandem bluff body configurations for enhanced flow-induced vibrations and energy harvesting potentialOcean Engineering · 2025