Regime transition between external air supply and turbulent entrainment in ventilated cavity flows
Fei Ma, Yuchen Liu, Wenming Zhang, Jianhua Wu, Wenyan Yu
Key points
From the paper's conclusion- The results show a consistent nonlinear response of cavity pressure deficit, cavity length, and air discharge to increasing ventilation capacity, characterized by an initial rapid variation followed by a subsequent weaker response or saturation.
Abstract
Aeration in high-speed free-surface flows is governed by the competition between externally supplied air and turbulence-induced air entrainment, yet the transition between these supply-limited and entrainment-limited states remains poorly understood. Systematic laboratory experiments were conducted by varying the relative ventilation area (Aa/Aw), where Aa denotes the total geometric ventilation area of the two ventilation shafts and Aw denotes the upstream flow area, thereby examining the competition between external air supply and turbulence-induced air entrainment. The results show a consistent nonlinear response of cavity pressure deficit, cavity length, and air discharge to increasing ventilation capacity, characterized by an initial rapid variation followed by a subsequent weaker response or saturation. A transition between the supply-limited and entrainment-limited regimes is inferred to occur at Aa/Aw ≈ 0.101, suggesting a shift in the dominant constraint from external air-supply capacity toward the entrainment capacity of the turbulent free surface. The dimensionless cavity pressure deficit (PN) is identified as an important hydraulic variable linking these two processes and provides an observable indicator of the imbalance between air-supply capacity and turbulence-induced air-entrainment demand. A combined scaling parameter, Π = (Aa/Aw)/Fr2.5, provides a reasonable empirical collapse of the cavity-pressure data in the supply-limited regime, supporting a unified empirical description of the effects of ventilation capacity and flow intensity on cavity pressure. The transition occurs near PN ≈ 0.02, suggesting that cavity pressure provides a measurable operational indicator of the governing flow regime under the present experimental conditions. These findings provide a pressure-based framework for interpreting the transition between supply-limited and entrainment-limited behavior, while the proposed criterion and scaling relationship remain configuration-dependent and require further validation under other flow and ventilation conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Water-driven air cavity flow and dispersion in a long partially full circular pipePhysics of Fluids · 2026
- Airflow Allocation and Driving Mechanisms in the Multi-Level Ventilation System of the Baihetan Spillway Tunnels: A Prototype-Scale CFD StudyWater · 2026
- Numerical Investigation of Downstream-Shaft Aeration and Air-Pocket Evolution in a Navigation-Lock Valve.Entropy (Basel, Switzerland) · 2026
- Experimental study of ventilated cavitation noise characteristicsPhysics of Fluids · 2025
- Experimental study of air-pocket-induced transient pressures in pipelinesJournal of Hydraulic Research · 2026
- Interfacial oscillations and internal flow dynamics of a freely closed ventilated supercavityPhysics of Fluids · 2026