Design of a diamond-based in-vessel soft x-ray camera system for the SPARC tokamak.
S Normile, D Vezinet, B Frandeen, C Perks, F Bombarda, G Verona-Rinati, J E Rice
Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA. · Commonwealth Fusion Systems, Devens, Massachusetts 01434, USA.
Key points
From the paper's conclusion- CVD diamonds have been used successfully for the detection of both vacuum ultraviolet and soft x-ray photons at the Frascati Tokamak Upgrade and have demonstrated the ability to maintain greater than 50% of their initial responsivity at a neutron fluence of 1016 cm−2.
Abstract
Soft x-ray tomography has been used in tokamaks for decades to interrogate a wide variety of phenomena; however, the standard silicon diodes coupled with beryllium filters will not be able to survive the high heat and neutron fluxes present in burning plasma devices like SPARC. Presented here is the design for a set of soft x-ray tomography cameras that use chemical vapor deposition (CVD) single-crystal diamonds and graphene filters for photodetection. Four of these cameras will be placed in the port plugs of SPARC with a large enough view of the poloidal cross section to enable tomographic inversion and sufficient time resolution to resolve the dynamics of low-m and -n magnetohydrodynamic modes. CVD diamonds have been used successfully for the detection of both vacuum ultraviolet and soft x-ray photons at the Frascati Tokamak Upgrade and have demonstrated the ability to maintain greater than 50% of their initial responsivity at a neutron fluence of 1016 cm-2. The neutron dose in SPARC will exceed this limit, providing a demonstration of how CVD diamonds fail in place while adding value to the early operation of a new tokamak. Numerical simulations indicate that graphene spectral filters will filter nearly as effectively as traditional beryllium ones and are able to resist significantly higher heat fluxes due to graphene's unique thermal properties. Simulated plasma emissivity profiles have been used to optimize both the camera placement and detector properties.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hard-x-ray diamond sensors for in-flight runaway electron detection on SPARC.The Review of scientific instruments · 2026
- Development of Sapphire-Based Solid-State Neutron Detectors for Fusion EnvironmentsarXiv · 2026
- Design and synthetic diagnostic of a vertical multi-energy soft x-ray camera for the WEST tokamak.The Review of scientific instruments · 2026
- Scalable selective-area diamond growth for thermal management applicationsApplied Physics Letters · 2026
- Advanced sensors for multi-color infrared imaging bolometers.The Review of scientific instruments · 2026
- Eu²⁺ ‐Doped Transparent Glass–Ceramics with Superior Scintillation Performance and Stability for High‐Resolution X‐Ray ImagingLaser & Photonics Review · 2025